A study of the identification properties and of the energy response of a Si-Si-CsI(Tl) ΔE-E telescope exploiting a partially depleted second Si stage has been performed. Five different bias voltages have been applied to the second stage of the telescope, one corresponding to full depletion, the others associated with a depleted layer ranging from 60% to 90% of the detector thickness. Fragment identification has been obtained using either the ΔE-E technique or the Pulse Shape Analysis (PSA). Charge collection efficiency has been evaluated. The ΔE-E performance is not affected by incomplete depletion. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds increase.

Extracting information from partially depleted Si detectors with digital sampling electronics / Pastore, G.; Pasquali, G.; Le Neindre, N.; Ademard, G.; Barlini, S.; Bini, M.; Bonnet, E.; Borderie, B.; Bougault, R.; Casini, G.; Chbihi, A.; Cinausero, M.; Dueñas, J.A.; Edelbruck, P.; Frankland, J.D.; Gramegna, F.; Gruyer, D.; Kordyasz, A.; Kozik, T.; Lopez, O.; Marchi, T.; Morelli, L.; Olmi, A.; Ordine, A.; Parlog, M.; Piantelli, S.; Poggi, G.; Rivet, M.-F.; Rosato, E.; Salomon, F.; Spadaccini, G.; Stefanini, A.A.; Valdŕe, S.; Vient, E.; Twaŕog, T.; Alba, R.; Maiolino, C.; Santonocito, D.. - In: EPJ WEB OF CONFERENCES. - ISSN 2101-6275. - STAMPA. - 88:(2015), pp. 01013-01016. (Intervento presentato al convegno 1st International Workshop on Multi Facets of EoS and Clustering, IWM-EC 2014 tenutosi a Dipartimento di Fisica e Astronomia and Laboratori Nazionali del Sud, ita nel 2014) [10.1051/epjconf/20158801013].

Extracting information from partially depleted Si detectors with digital sampling electronics

PASTORE, GIUSEPPE;PASQUALI, GABRIELE;BARLINI, SANDRO;BINI, MAURIZIO;OLMI, ALESSANDRO;POGGI, GIACOMO;STEFANINI, ANDREA;VALDRE', SIMONE;
2015

Abstract

A study of the identification properties and of the energy response of a Si-Si-CsI(Tl) ΔE-E telescope exploiting a partially depleted second Si stage has been performed. Five different bias voltages have been applied to the second stage of the telescope, one corresponding to full depletion, the others associated with a depleted layer ranging from 60% to 90% of the detector thickness. Fragment identification has been obtained using either the ΔE-E technique or the Pulse Shape Analysis (PSA). Charge collection efficiency has been evaluated. The ΔE-E performance is not affected by incomplete depletion. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds increase.
2015
EPJ Web of Conferences
1st International Workshop on Multi Facets of EoS and Clustering, IWM-EC 2014
Dipartimento di Fisica e Astronomia and Laboratori Nazionali del Sud, ita
2014
Pastore, G.; Pasquali, G.; Le Neindre, N.; Ademard, G.; Barlini, S.; Bini, M.; Bonnet, E.; Borderie, B.; Bougault, R.; Casini, G.; Chbihi, A.; Cinausero, M.; Dueñas, J.A.; Edelbruck, P.; Frankland, J.D.; Gramegna, F.; Gruyer, D.; Kordyasz, A.; Kozik, T.; Lopez, O.; Marchi, T.; Morelli, L.; Olmi, A.; Ordine, A.; Parlog, M.; Piantelli, S.; Poggi, G.; Rivet, M.-F.; Rosato, E.; Salomon, F.; Spadaccini, G.; Stefanini, A.A.; Valdŕe, S.; Vient, E.; Twaŕog, T.; Alba, R.; Maiolino, C.; Santonocito, D.
File in questo prodotto:
File Dimensione Formato  
epjconf_ec2014_01013.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 465.8 kB
Formato Adobe PDF
465.8 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1065520
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact