A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. Herein, a rapid procedure based on QuEChERS-like extraction approach followed by solid phase purification was optimized for PBDE extraction from mussel samples. The detection limits for both the immunoassays, calculated as BDE-47 equivalent concentration, were 0.6 ng g-1 and 1.1 ng g-1, respectively. Real mussel samples, including a Certified Reference Material (CRM), were analyzed. The samples were investigated by colorimetric and electrochemical immunoassays as well as by GC-MS. In comparison to GC-MS results, 106 and 102 % relative accuracy were obtained for the colorimetric and electrochemical immunoassays, respectively. The proposed method could be useful for massive environmental campaigns, being able to rapidly detect possible polluted seafood samples.

Evaluation of a QuEChERS-like extraction approach for the determination of PBDEs in mussels by immuno-assay-based screening methods / Romanelli, Sara; Bettazzi, Francesca; Martellini, Tania; Shelver, Weilin L.; Cincinelli, Alessandra; Galarini, Roberta; Palchetti, Ilaria. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 170:(2017), pp. 540-545. [10.1016/j.talanta.2017.04.027]

Evaluation of a QuEChERS-like extraction approach for the determination of PBDEs in mussels by immuno-assay-based screening methods

ROMANELLI, SARA;BETTAZZI, FRANCESCA;MARTELLINI, TANIA;CINCINELLI, ALESSANDRA;PALCHETTI, ILARIA
2017

Abstract

A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. Herein, a rapid procedure based on QuEChERS-like extraction approach followed by solid phase purification was optimized for PBDE extraction from mussel samples. The detection limits for both the immunoassays, calculated as BDE-47 equivalent concentration, were 0.6 ng g-1 and 1.1 ng g-1, respectively. Real mussel samples, including a Certified Reference Material (CRM), were analyzed. The samples were investigated by colorimetric and electrochemical immunoassays as well as by GC-MS. In comparison to GC-MS results, 106 and 102 % relative accuracy were obtained for the colorimetric and electrochemical immunoassays, respectively. The proposed method could be useful for massive environmental campaigns, being able to rapidly detect possible polluted seafood samples.
2017
170
540
545
Romanelli, Sara; Bettazzi, Francesca; Martellini, Tania; Shelver, Weilin L.; Cincinelli, Alessandra; Galarini, Roberta; Palchetti, Ilaria
File in questo prodotto:
File Dimensione Formato  
Talanta 2017.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 646.37 kB
Formato Adobe PDF
646.37 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1080061
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact