In this paper the authors describe the development and the characterization of a Quartz Crystal Microbalance (QCM) sensor for N02 detection with the sensitive layer made of a thin films of poly (3,4-ethylenedioxythiophene) (PEDOT). The PEDOT layer was obtained by electropolymerization on one of the gold electrodes of a 10 MHz AT-cut commercial quartz crystal. The sensor performance in terms of sensitivity and selectivity were assessed exploiting an ad hoc chemical sampling unit, and a low noise conditioning and processing electronic system. This latter consists of an oscillator hosting the piezoelectric resonator, and of a frequency measurement system granting a (short time) relative accuracy of approximately 10-8 , which ensures a mass resolution in the order of the ng. The preliminary obtained results show a N02 resolution and sensitivity of the order of 1 ppm, and 2.6 Hz/ppm, respectively, at 35°C constant room temperature and in a dry environment, and show that a satisfactory repeatability can be achieved with recovery cycles in N2 at room temperature.

NO<inf>2</inf> QCM gas sensor based on electrochemical deposition of PEDOT / Fort, A.; Innocenti, M.; Foresti, M. L.; Mugnaini, M.; Pasquini, I.; Pigani, L.; Rocchi, S.; Vignoli, V.. - ELETTRONICO. - (2009), pp. 184-187. (Intervento presentato al convegno IWASI 2009 , 3rd International) [10.1109/IWASI.2009.5184792].

NO2 QCM gas sensor based on electrochemical deposition of PEDOT

Innocenti, M.;Foresti, M. L.;
2009

Abstract

In this paper the authors describe the development and the characterization of a Quartz Crystal Microbalance (QCM) sensor for N02 detection with the sensitive layer made of a thin films of poly (3,4-ethylenedioxythiophene) (PEDOT). The PEDOT layer was obtained by electropolymerization on one of the gold electrodes of a 10 MHz AT-cut commercial quartz crystal. The sensor performance in terms of sensitivity and selectivity were assessed exploiting an ad hoc chemical sampling unit, and a low noise conditioning and processing electronic system. This latter consists of an oscillator hosting the piezoelectric resonator, and of a frequency measurement system granting a (short time) relative accuracy of approximately 10-8 , which ensures a mass resolution in the order of the ng. The preliminary obtained results show a N02 resolution and sensitivity of the order of 1 ppm, and 2.6 Hz/ppm, respectively, at 35°C constant room temperature and in a dry environment, and show that a satisfactory repeatability can be achieved with recovery cycles in N2 at room temperature.
2009
Advances in Sensors and Interfaces
IWASI 2009 , 3rd International
Fort, A.; Innocenti, M.; Foresti, M. L.; Mugnaini, M.; Pasquini, I.; Pigani, L.; Rocchi, S.; Vignoli, V.
File in questo prodotto:
File Dimensione Formato  
fort2009.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 684.79 kB
Formato Adobe PDF
684.79 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1107693
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact