Gas turbine performances are directly related to outside conditions. The use of gas turbines in combined gas-steam power plants, also applied to cogeneration, increases performance dependence by outside conditions, because plants boundary conditions become more complex. In recent years, inlet air cooling systems have been introduced to control air temperature and humidity at compressor inlet resulting in an increase in plant power and efficiency. In this paper, the dependence of outside conditions for an existing cogenerative plant, located in Tuscany (Italy), is studied. The plant is equipped with two GE-LM6000 aeroderivative gas-turbines coupled with a three pressure level heat recovery steam generator, cogenerative application being related to the industrial district. The ambient temperature has been found to be the most important factor affecting the plant performance, but relative air humidity variation also has considerable effects. The field performance data are compared with a numerical simulation. The simulation results show a good agreement with the field performance data. The simulation allows evaluation of design and off-design plant performance and can become a useful tool to study the outside condition influence on power plant performance.

INFLUENCE OF AMBIENT CONDITIONS ON AN AERODERIVATIVE GAS TURBINE BASED COGENERATION PLANT. A COMPARISON OF NUMERICAL SIMULATION WITH FIEL PERFORMANCE DATA / B. FACCHINI; C. CARCASCI; F. GRILLO. - STAMPA. - 3:(2000), pp. 1-10. (Intervento presentato al convegno ASME PAPER 2000-GT-0313.IGTI TURBO EXPO tenutosi a MUNCHEN nel 8 May 2000).

INFLUENCE OF AMBIENT CONDITIONS ON AN AERODERIVATIVE GAS TURBINE BASED COGENERATION PLANT. A COMPARISON OF NUMERICAL SIMULATION WITH FIEL PERFORMANCE DATA

FACCHINI, BRUNO;CARCASCI, CARLO;
2000

Abstract

Gas turbine performances are directly related to outside conditions. The use of gas turbines in combined gas-steam power plants, also applied to cogeneration, increases performance dependence by outside conditions, because plants boundary conditions become more complex. In recent years, inlet air cooling systems have been introduced to control air temperature and humidity at compressor inlet resulting in an increase in plant power and efficiency. In this paper, the dependence of outside conditions for an existing cogenerative plant, located in Tuscany (Italy), is studied. The plant is equipped with two GE-LM6000 aeroderivative gas-turbines coupled with a three pressure level heat recovery steam generator, cogenerative application being related to the industrial district. The ambient temperature has been found to be the most important factor affecting the plant performance, but relative air humidity variation also has considerable effects. The field performance data are compared with a numerical simulation. The simulation results show a good agreement with the field performance data. The simulation allows evaluation of design and off-design plant performance and can become a useful tool to study the outside condition influence on power plant performance.
2000
ASME Turbo Expo 2000: Power for Land, Sea, and Air, GT 2000
ASME PAPER 2000-GT-0313.IGTI TURBO EXPO
MUNCHEN
8 May 2000
B. FACCHINI; C. CARCASCI; F. GRILLO
File in questo prodotto:
File Dimensione Formato  
26_00_ASME_2000-GT-313_ambientCondition.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 2.53 MB
Formato Adobe PDF
2.53 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/23064
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact