We here reported the development and application of an immobilized enzyme reactor (IMER) based on beta-glucuronidase to the on-line determination of urinary molar ratios of dextromethorphan (DOMe)/dextrorphan (DOH) for the assessment of the metabolic activity of CYP2D6, a genetically variable isoform of cytochrome P-450 (CYP). beta-Glucuronidase was immobilized on an HPLC monolithic aminopropyl silica support. Catalytic activity and stability of the chromatographic reactor were evaluated using 8-hydroxyquinoline glucuronide (8-HQG) as substrate. The IMER was coupled through a switching valve to a reversed-phase column (C8) for the simultaneous determination of dextromethorphan and its main metabolite dextrorphan. On purpose a selective reversed-phase ion pair HPLC method coupled with fluorescence detection was developed. Urine samples were first centrifuged to remove insoluble materials and then aliquots of the supernatants were injected into the coupled-column analyser. Linearity, precision and accuracy of the method were established. The method reliability was verified by comparing our data with previous data of a phenotyping study carried out by the Poison Control Centre of Pavia-Clinical Toxicology Division.

Development of a chromatographic bioreactor based on immobilized -glucuronidase on monolithic support for the determination of dextromethorphan and dextrorphan in human urine / E. CALLERI; G. MARRUBINI; G. MASSOLINI; D. LUBDA; S. DE FAZIO; S. FURLANETTO; I. WAINER; L. MANZO; G. CACCIALANZA. - In: JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS. - ISSN 0731-7085. - STAMPA. - 35:(2004), pp. 1179-1189.

Development of a chromatographic bioreactor based on immobilized -glucuronidase on monolithic support for the determination of dextromethorphan and dextrorphan in human urine.

FURLANETTO, SANDRA;
2004

Abstract

We here reported the development and application of an immobilized enzyme reactor (IMER) based on beta-glucuronidase to the on-line determination of urinary molar ratios of dextromethorphan (DOMe)/dextrorphan (DOH) for the assessment of the metabolic activity of CYP2D6, a genetically variable isoform of cytochrome P-450 (CYP). beta-Glucuronidase was immobilized on an HPLC monolithic aminopropyl silica support. Catalytic activity and stability of the chromatographic reactor were evaluated using 8-hydroxyquinoline glucuronide (8-HQG) as substrate. The IMER was coupled through a switching valve to a reversed-phase column (C8) for the simultaneous determination of dextromethorphan and its main metabolite dextrorphan. On purpose a selective reversed-phase ion pair HPLC method coupled with fluorescence detection was developed. Urine samples were first centrifuged to remove insoluble materials and then aliquots of the supernatants were injected into the coupled-column analyser. Linearity, precision and accuracy of the method were established. The method reliability was verified by comparing our data with previous data of a phenotyping study carried out by the Poison Control Centre of Pavia-Clinical Toxicology Division.
2004
35
1179
1189
E. CALLERI; G. MARRUBINI; G. MASSOLINI; D. LUBDA; S. DE FAZIO; S. FURLANETTO; I. WAINER; L. MANZO; G. CACCIALANZA
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/312241
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 18