This paper reports some results from a research work focused on the analysis and interpretation of the damage pattern in the Dome of the Siena Cathedral (Italy). The research was motivated by the failure of some elements of the internal stone-truss system connecting the two masonry shells which constitute the Dome structure. Reported data represent the main results obtained from an in-situ survey; then, numerical analyses performed to obtain the static identification of the monument as well as to assess the possible causes that may have led to the observed static problems are described. The numerical modeling was performed by steps, from linear and quite simple models built with plane elements up to non linear models with three-dimensional elements. The non linear FEM, performed with respect to a series of in situ measures, allowed to reproduce the behavior of the monument and to give a first interpretation of the causes for the structural static problems. A preliminary evaluation of the building’s static safety was assessed to account for the observed failure of the stone-trusses system.

In situ testing and structural assessment of an historic masonry dome / G. Bartoli; M. Betti; M. Orlando; P. Spinelli. - ELETTRONICO. - (2008), pp. 1-13. (Intervento presentato al convegno SF&R2008 – 12th International Conference on Structural Faults and Repair tenutosi a Edimburgo, Scozia nel 10-12 giugno 2008).

In situ testing and structural assessment of an historic masonry dome

BARTOLI, GIANNI;BETTI, MICHELE;ORLANDO, MAURIZIO;SPINELLI, PAOLO
2008

Abstract

This paper reports some results from a research work focused on the analysis and interpretation of the damage pattern in the Dome of the Siena Cathedral (Italy). The research was motivated by the failure of some elements of the internal stone-truss system connecting the two masonry shells which constitute the Dome structure. Reported data represent the main results obtained from an in-situ survey; then, numerical analyses performed to obtain the static identification of the monument as well as to assess the possible causes that may have led to the observed static problems are described. The numerical modeling was performed by steps, from linear and quite simple models built with plane elements up to non linear models with three-dimensional elements. The non linear FEM, performed with respect to a series of in situ measures, allowed to reproduce the behavior of the monument and to give a first interpretation of the causes for the structural static problems. A preliminary evaluation of the building’s static safety was assessed to account for the observed failure of the stone-trusses system.
2008
Proceedings of the Twelfth International Conference "Structural Faults and Repair - 2008"
SF&R2008 – 12th International Conference on Structural Faults and Repair
Edimburgo, Scozia
10-12 giugno 2008
G. Bartoli; M. Betti; M. Orlando; P. Spinelli
File in questo prodotto:
File Dimensione Formato  
53-2008 CI Cupola Siena SF&R08.pdf

Accesso chiuso

Descrizione: Articolo principale
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.84 MB
Formato Adobe PDF
1.84 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/330511
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact