Abstract This study was performed to evaluate the reliability of transcutaneous oximetry as compared with strain gauge plethysmography and with Doppler in the assessment of the initial peripheral vascular disease in diabetics who are still asymptomatic. Twenty-five diabetics (38 lower extremities) with different degrees of peripheral vascular disease, classified according to Fontaine, were investigated. Ten healthy subjects (16 lower extremities) served as controls. In the first group of patients (still asymptomatic) it was possible to select by transcutaneous oximetry and by plethysmography a subpopulation that presented a significant reduction in the arterial flow of the limbs. Moreover, a significant correlation between data obtained by strain gauge plethysmography and transcutaneous oximetry was found (p less than 0.001), whereas correlation with data from Doppler was lacking.

Transcutaneous oximetry in evaluation of the initial peripheral artery disease in diabetics / PA.Modesti; M.Boddi; L.Poggesi; GF.Gensini; GG.Neri Serneri. - In: ANGIOLOGY. - ISSN 0003-3197. - STAMPA. - 38:(1987), pp. 457-462. [10.1177/000331978703800605]

Transcutaneous oximetry in evaluation of the initial peripheral artery disease in diabetics

MODESTI, PIETRO AMEDEO;BODDI, MARIA;POGGESI, LOREDANA;GENSINI, GIAN FRANCO;NERI SERNERI, GIAN GASTONE
1987

Abstract

Abstract This study was performed to evaluate the reliability of transcutaneous oximetry as compared with strain gauge plethysmography and with Doppler in the assessment of the initial peripheral vascular disease in diabetics who are still asymptomatic. Twenty-five diabetics (38 lower extremities) with different degrees of peripheral vascular disease, classified according to Fontaine, were investigated. Ten healthy subjects (16 lower extremities) served as controls. In the first group of patients (still asymptomatic) it was possible to select by transcutaneous oximetry and by plethysmography a subpopulation that presented a significant reduction in the arterial flow of the limbs. Moreover, a significant correlation between data obtained by strain gauge plethysmography and transcutaneous oximetry was found (p less than 0.001), whereas correlation with data from Doppler was lacking.
1987
38
457
462
PA.Modesti; M.Boddi; L.Poggesi; GF.Gensini; GG.Neri Serneri
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/331905
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 13
social impact