A design hypothesis to rebuild the main wing of the medieval castle of Prampero, devastated by a violent earthquake in Friuli in 1976, is presented in this paper. The intervention suggests that the building be used as a museum to exhibit the artistic heritage of the owners. This new destination prompted some architectural rearrangements of the interiors of the building as compared to its original configuration, while preserving the global volume and the interstory heights, as well as the outer appearance of the castle, including its façades, the roof and all finishes. The structural design includes some updated traditional solutions for the masonry walls, the wooden floors and the roof. At the same time, a non-conventional solution is adopted for the floor accommodating the main exhibition hall, consisting in the incorporation of a base isolation seismic protection system. Details of the design analyses carried out, with special regard to the numerical enquiry developed on the base-isolated floor, are provided in this paper. Selected drawings of the technical solutions adopted, are also presented.

Rebuilding of an ancient castle including a base-isolated museum hall / S. Sorace; G. Terenzi. - STAMPA. - 95:(2007), pp. 419-428. (Intervento presentato al convegno X International Conference on Structural Studies Repairs and Maintenance of Heritage Architecture - STREMAH 2007 tenutosi a Prague, Czech Republic nel 4-6 July, 2007) [10.2495/STR070391].

Rebuilding of an ancient castle including a base-isolated museum hall

TERENZI, GLORIA
2007

Abstract

A design hypothesis to rebuild the main wing of the medieval castle of Prampero, devastated by a violent earthquake in Friuli in 1976, is presented in this paper. The intervention suggests that the building be used as a museum to exhibit the artistic heritage of the owners. This new destination prompted some architectural rearrangements of the interiors of the building as compared to its original configuration, while preserving the global volume and the interstory heights, as well as the outer appearance of the castle, including its façades, the roof and all finishes. The structural design includes some updated traditional solutions for the masonry walls, the wooden floors and the roof. At the same time, a non-conventional solution is adopted for the floor accommodating the main exhibition hall, consisting in the incorporation of a base isolation seismic protection system. Details of the design analyses carried out, with special regard to the numerical enquiry developed on the base-isolated floor, are provided in this paper. Selected drawings of the technical solutions adopted, are also presented.
2007
Studies, Repairs and Maintenance of Heritage Architecture
X International Conference on Structural Studies Repairs and Maintenance of Heritage Architecture - STREMAH 2007
Prague, Czech Republic
4-6 July, 2007
S. Sorace; G. Terenzi
File in questo prodotto:
File Dimensione Formato  
STREMAH07_Sorace_Terenzi.pdf

accesso aperto

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 374.66 kB
Formato Adobe PDF
374.66 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/342256
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact