Objective: To test the hypothesis that there is no difference between the frictional forces produced by a passive self-ligating bracket (SLB) in vitro and a conventional bracket (CB) used with two types of elastomeric ligatures. Materials and Method: The brackets, wires and ligation methods used in vitro were a passive SLB and a CB used with two types of elastomeric ligatures (conventional elastomeric ligature [CEL] and unconventional elastomeric ligatures [UEL]). The bracket ligation systems were tested with two types of wires (0.014″ super elastic nickel titanium wire and 0.019″ × 0.025″ stainless steel wire). Resistance to sliding of the bracket/wire/ligature systems was measured with an experimental model mounted on the crosshead of an Instron testing machine with a 10 N load cell. Each sample was tested 10 consecutive times under a dry state. Results: Frictional forces close to 0 g were recorded in all tests with SLB and in all tests with UEL on CB with both wire types. Resistance to sliding increased significantly (87-177 g) (P < .05) when CEL on CB was used with both wires. Conclusion: UELs may represent a valid alternative to passive SLBs for low-friction biomechanics.

In vitro frictional forces generated by three different ligation methods / P. Gandini; L. Orsi; C. Bertoncini; S. Massironi; L. Franchi. - In: ANGLE ORTHODONTIST. - ISSN 0003-3219. - STAMPA. - 78:(2008), pp. 917-921.

In vitro frictional forces generated by three different ligation methods

FRANCHI, LORENZO
2008

Abstract

Objective: To test the hypothesis that there is no difference between the frictional forces produced by a passive self-ligating bracket (SLB) in vitro and a conventional bracket (CB) used with two types of elastomeric ligatures. Materials and Method: The brackets, wires and ligation methods used in vitro were a passive SLB and a CB used with two types of elastomeric ligatures (conventional elastomeric ligature [CEL] and unconventional elastomeric ligatures [UEL]). The bracket ligation systems were tested with two types of wires (0.014″ super elastic nickel titanium wire and 0.019″ × 0.025″ stainless steel wire). Resistance to sliding of the bracket/wire/ligature systems was measured with an experimental model mounted on the crosshead of an Instron testing machine with a 10 N load cell. Each sample was tested 10 consecutive times under a dry state. Results: Frictional forces close to 0 g were recorded in all tests with SLB and in all tests with UEL on CB with both wire types. Resistance to sliding increased significantly (87-177 g) (P < .05) when CEL on CB was used with both wires. Conclusion: UELs may represent a valid alternative to passive SLBs for low-friction biomechanics.
2008
78
917
921
P. Gandini; L. Orsi; C. Bertoncini; S. Massironi; L. Franchi
File in questo prodotto:
File Dimensione Formato  
090607-420%2E1(2).pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 158.47 kB
Formato Adobe PDF
158.47 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/347065
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 28
social impact