In past years, seismic response of asymmetric structures has been frequently analysed by means of single-storey models, because of their simplicity and low computational cost. However, it is widely believed that use of more realistic multi-storey models is needed in order to investigate effects of some system characteristics (such as overstrength, higher modes of vibration, etc.) that make behaviour of multi-storey schemes different from that of single-storey systems. This paper examines effects of the overstrength in element cross-sections on the seismic behaviour of multi-storey asymmetric buildings. It is shown that in actual buildings this characteristic, which is sometimes very variable both in plan and along the height of the building, may lead to distributions of ductility demands different from those expected according to the results from single-storey models. Consequently, torsional provisions, which aim at reducing ductility demands of single-storey asymmetric systems to those of the corresponding torsionally balanced systems, should be re-checked in light of the behaviour of realistic multi-storey buildings.

Effect of overstrength on the seismic behaviour of multi-storey regularly asymmetric buildings / M. DE STEFANO; E.M. MARINO; P.P. ROSSI. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - STAMPA. - 4:(2006), pp. 23-42. [10.1007/s10518-005-5408-8]

Effect of overstrength on the seismic behaviour of multi-storey regularly asymmetric buildings

DE STEFANO, MARIO;
2006

Abstract

In past years, seismic response of asymmetric structures has been frequently analysed by means of single-storey models, because of their simplicity and low computational cost. However, it is widely believed that use of more realistic multi-storey models is needed in order to investigate effects of some system characteristics (such as overstrength, higher modes of vibration, etc.) that make behaviour of multi-storey schemes different from that of single-storey systems. This paper examines effects of the overstrength in element cross-sections on the seismic behaviour of multi-storey asymmetric buildings. It is shown that in actual buildings this characteristic, which is sometimes very variable both in plan and along the height of the building, may lead to distributions of ductility demands different from those expected according to the results from single-storey models. Consequently, torsional provisions, which aim at reducing ductility demands of single-storey asymmetric systems to those of the corresponding torsionally balanced systems, should be re-checked in light of the behaviour of realistic multi-storey buildings.
2006
4
23
42
M. DE STEFANO; E.M. MARINO; P.P. ROSSI
File in questo prodotto:
File Dimensione Formato  
De stefano Marino 2006.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 242.64 kB
Formato Adobe PDF
242.64 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/354222
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 24
social impact