FRP reinforcement is well known as a possible alternative to steel bars in order to improve durability of reinforced concrete members. However, the intrinsic brittleness of concrete and FRP materials may induce problems at the ultimate conditions due to premature failure modes; the performance under service loads is a critical issue as well. To investigate response of concrete members reinforced with longitudinal glass or carbon FRP bars without shear reinforcement, an experimental program has been developed at the Department of Constructions of the University of Florence. The sixteen specimens designed and cast within this project were characterized by different study variables concerning section geometry, concrete grade and type of reinforcement. The results of tests performed on FRP-reinforced specimens are presented in this paper. In par-ticular, different failure modes due to flexure and shear have been observed; response under load levels simu-lating service conditions has been also examined. Results of FRP-reinforced specimens have been compared with those given by control specimens provided with conventional steel bars. Finally, analytical procedures to evaluate immediate deflections of FRP-reinforced members have been assessed.
Experimental investigation on flexural response of concrete members reinforced with FRP bars / A. Acciai; R. Nudo. - STAMPA. - (2009), pp. 1-10.
Experimental investigation on flexural response of concrete members reinforced with FRP bars
NUDO, RAFFAELE
2009
Abstract
FRP reinforcement is well known as a possible alternative to steel bars in order to improve durability of reinforced concrete members. However, the intrinsic brittleness of concrete and FRP materials may induce problems at the ultimate conditions due to premature failure modes; the performance under service loads is a critical issue as well. To investigate response of concrete members reinforced with longitudinal glass or carbon FRP bars without shear reinforcement, an experimental program has been developed at the Department of Constructions of the University of Florence. The sixteen specimens designed and cast within this project were characterized by different study variables concerning section geometry, concrete grade and type of reinforcement. The results of tests performed on FRP-reinforced specimens are presented in this paper. In par-ticular, different failure modes due to flexure and shear have been observed; response under load levels simu-lating service conditions has been also examined. Results of FRP-reinforced specimens have been compared with those given by control specimens provided with conventional steel bars. Finally, analytical procedures to evaluate immediate deflections of FRP-reinforced members have been assessed.File | Dimensione | Formato | |
---|---|---|---|
adv_cs.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
10.01 MB
Formato
Adobe PDF
|
10.01 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.