To describe the features of low-friction ligatures during the leveling and aligning phase of fixed appliance therapy with preadjusted brackets.Experimental in vitro and in vivo studies were carried out to test the performance of the low-friction system with regard to leveling and aligning of the dental arches, as well as to increasing the transverse dimension of the maxillary arch.The outcomes of experimental testing showed that the combination of the low-friction ligatures with the superelastic nickel-titanium wires produced a significantly smaller amount of binding at the bracket/archwire/ligature unit when compared to conventional elastomeric ligatures.The biomechanical consequences of the use of low-friction ligatures were shorter duration of orthodontic treatment during the leveling and aligning phase, concurrent dentoalveolar expansion of the dental arch, and the possibility of using biologically adequate orthodontic forces.

Orthodontic treatment with preadjusted appliances and low-friction ligatures: experimental evidence and clinical observations / T. Baccetti;L. Franchi;A. Fortini. - In: WORLD JOURNAL OF ORTHODONTICS. - ISSN 1530-5678. - STAMPA. - 9:(2008), pp. 7-13.

Orthodontic treatment with preadjusted appliances and low-friction ligatures: experimental evidence and clinical observations.

BACCETTI, TIZIANO;FRANCHI, LORENZO;
2008

Abstract

To describe the features of low-friction ligatures during the leveling and aligning phase of fixed appliance therapy with preadjusted brackets.Experimental in vitro and in vivo studies were carried out to test the performance of the low-friction system with regard to leveling and aligning of the dental arches, as well as to increasing the transverse dimension of the maxillary arch.The outcomes of experimental testing showed that the combination of the low-friction ligatures with the superelastic nickel-titanium wires produced a significantly smaller amount of binding at the bracket/archwire/ligature unit when compared to conventional elastomeric ligatures.The biomechanical consequences of the use of low-friction ligatures were shorter duration of orthodontic treatment during the leveling and aligning phase, concurrent dentoalveolar expansion of the dental arch, and the possibility of using biologically adequate orthodontic forces.
2008
9
7
13
T. Baccetti;L. Franchi;A. Fortini
File in questo prodotto:
File Dimensione Formato  
wjo_9_1_Baccetti_2.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 146.39 kB
Formato Adobe PDF
146.39 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/402298
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact