In the coming years, biomedical instrument manufacturers will have to inform the Notified Body of RoHS conformity assessment of the new medical instruments. In particular, in the case of lead-free solders, the Notified Body will require evidence that such solders are equally reliable as tin-lead, for the proposed use and lifetime of the product. So, biomedical instrument manufacturers are strongly interested in evaluating the performance of new soldering lead-free material used for the implementation of electronic parts. In order to support them and fill the technology knowledge gap, this paper presents a novel 128-channel phased-array probe for echocardiograph applications realized by new soldering technique where isotropic silver electrically conductive adhesive is used. In particular, the new soldering material is taken into consideration in the design phase of ultrasound array transducer, which is the core of a linear phased-array probe that is able to monitor the cardiac muscle. Being such material innovative in the application, a detailed study of the failure condition regarding the phased-array probe by means of accelerated qualification testing is proposed in order to assure its performances under stress and over time. A comparison of the electroacoustic measurement results with respect to the conventional probe, soldered with Sn-Pb, is also presented in this paper.

Experimental Stress Characterization of a Biomedical Ultrasound Probe Soldered with Innovative Silver Isotropically Conductive Adhesive / M. Catelani; V. L. Scarano; F. Bertocci. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 61:(2012), pp. 719-728.

Experimental Stress Characterization of a Biomedical Ultrasound Probe Soldered with Innovative Silver Isotropically Conductive Adhesive

CATELANI, MARCANTONIO;
2012

Abstract

In the coming years, biomedical instrument manufacturers will have to inform the Notified Body of RoHS conformity assessment of the new medical instruments. In particular, in the case of lead-free solders, the Notified Body will require evidence that such solders are equally reliable as tin-lead, for the proposed use and lifetime of the product. So, biomedical instrument manufacturers are strongly interested in evaluating the performance of new soldering lead-free material used for the implementation of electronic parts. In order to support them and fill the technology knowledge gap, this paper presents a novel 128-channel phased-array probe for echocardiograph applications realized by new soldering technique where isotropic silver electrically conductive adhesive is used. In particular, the new soldering material is taken into consideration in the design phase of ultrasound array transducer, which is the core of a linear phased-array probe that is able to monitor the cardiac muscle. Being such material innovative in the application, a detailed study of the failure condition regarding the phased-array probe by means of accelerated qualification testing is proposed in order to assure its performances under stress and over time. A comparison of the electroacoustic measurement results with respect to the conventional probe, soldered with Sn-Pb, is also presented in this paper.
2012
61
719
728
M. Catelani; V. L. Scarano; F. Bertocci
File in questo prodotto:
File Dimensione Formato  
tim_2012.pdf

Accesso chiuso

Descrizione: tim_2012
Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 1 MB
Formato Adobe PDF
1 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/606127
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact