Four position sensitive silicon detectors have been tested inside the Tevatron beam pipe at Fermilab. The system is the prototype of the small angle silicon spectrometer designed to study primarily View the MathML source elastic and diffractive cross-sections at the Collider of Fermilab (CDF). Particles in the beam halo during View the MathML source storage tests were used to study the performance of the detectors. Efficiency, linearity of response and spatial resolution are shown. Measurements performed at different distances from the beam axis have shown that the detectors could be operated at 8.5 mm from the beam with low rates and no disturbance to the circulating beams. This distance corresponds to about 11 times the standard half-width of the local beam envelope. The behaviour of the detectors with the radiation dose has also been investigated.

Position sensitive silicon detectors inside the tevatron collider / G. Apollinari;F. Bedeschi;G. Bellettini;F. Bosi;L. Bosisio;F. Cervelli;R. Del Fabbro;M. Dell'orso;A. Di Virgilio;E. Focardi;P. Giannetti;M. Giorgi;A. Menzione;L. Ristori;A. Scribano;P. Sestini;A. Stefanini;G. Tonelli;F. Zetti;S. Bertolucci;M. Cordelli;M. Curatolo;B. Dulach;B. Esposito;P. Giromini;S. Miscetti;A. Sansoni;S. Belforte;T. Chapin;G. Chiarelli;N. Giokaris;K. Goulianos;R. Plunkett;S.N. White. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - ELETTRONICO. - 252:(1986), pp. 467-470. [10.1016/0168-9002(86)91225-8]

Position sensitive silicon detectors inside the tevatron collider

FOCARDI, ETTORE;
1986

Abstract

Four position sensitive silicon detectors have been tested inside the Tevatron beam pipe at Fermilab. The system is the prototype of the small angle silicon spectrometer designed to study primarily View the MathML source elastic and diffractive cross-sections at the Collider of Fermilab (CDF). Particles in the beam halo during View the MathML source storage tests were used to study the performance of the detectors. Efficiency, linearity of response and spatial resolution are shown. Measurements performed at different distances from the beam axis have shown that the detectors could be operated at 8.5 mm from the beam with low rates and no disturbance to the circulating beams. This distance corresponds to about 11 times the standard half-width of the local beam envelope. The behaviour of the detectors with the radiation dose has also been investigated.
1986
252
467
470
G. Apollinari;F. Bedeschi;G. Bellettini;F. Bosi;L. Bosisio;F. Cervelli;R. Del Fabbro;M. Dell'orso;A. Di Virgilio;E. Focardi;P. Giannetti;M. Giorgi;A. Menzione;L. Ristori;A. Scribano;P. Sestini;A. Stefanini;G. Tonelli;F. Zetti;S. Bertolucci;M. Cordelli;M. Curatolo;B. Dulach;B. Esposito;P. Giromini;S. Miscetti;A. Sansoni;S. Belforte;T. Chapin;G. Chiarelli;N. Giokaris;K. Goulianos;R. Plunkett;S.N. White
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/625783
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact