In this paper an analytical model to evaluate the structural behavior of masonry arches and vaults strengthened with composite unbonded tendons placed at the extrados is presented. The tendons are fixed at the imposts. The model is formulated under the assumption of finite displacements. The displaced equilibrium configurations are identified by the stationarity of the potential of the acting forces. It is shown that when the tendon is not pretensioned an increase of the arch collapse load can be achieved only if the axial stiffness of the tendon is sufficiently large. Instead if the tendon is pretensioned an increase of the load that induces the first displacement of the arch is always achieved. If the stiffness of the tendon is sufficiently large the collapse load will be greater than the load that produces the first displacement of the arch.

Masonry arches strengthened with composite unbonded tendons / A. D'Ambrisi; L. Feo; F. Focacci. - In: COMPOSITE STRUCTURES. - ISSN 0263-8223. - STAMPA. - 98:(2013), pp. 323-329. [10.1016/j.compstruct.2012.10.040]

Masonry arches strengthened with composite unbonded tendons

D'AMBRISI, ANGELO;
2013

Abstract

In this paper an analytical model to evaluate the structural behavior of masonry arches and vaults strengthened with composite unbonded tendons placed at the extrados is presented. The tendons are fixed at the imposts. The model is formulated under the assumption of finite displacements. The displaced equilibrium configurations are identified by the stationarity of the potential of the acting forces. It is shown that when the tendon is not pretensioned an increase of the arch collapse load can be achieved only if the axial stiffness of the tendon is sufficiently large. Instead if the tendon is pretensioned an increase of the load that induces the first displacement of the arch is always achieved. If the stiffness of the tendon is sufficiently large the collapse load will be greater than the load that produces the first displacement of the arch.
2013
98
323
329
A. D'Ambrisi; L. Feo; F. Focacci
File in questo prodotto:
File Dimensione Formato  
Masonry arches strengthened with composite unbonded tendons.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 917.13 kB
Formato Adobe PDF
917.13 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/772569
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 57
  • ???jsp.display-item.citation.isi??? 48
social impact