A spectrophotometric method, based on the electronic absorption and second-derivative spectra of beef drip, has been developed to detect the amount of carbon monoxide bound to myoglobin in treated beef samples. The method has been validated following the criteria reported in the Eurachem guides. The limit of detection, equal to 0.14 mu m, has been evaluated analysing ten blank samples, taking into account the mean concentration and the resulting standard deviations. The accuracy of the method has been studied in terms of trueness and precision; the first is expressed as per cent recovery (always exceeding 90%) and the second as relative standard deviation. The method is easy, rapid and allows one to determine qualitatively and quantitatively the CO concentration in the meat drip, by simply measuring in the UVVis spectrum of an unknown sample the absorbance values at three specific wavelengths: 423, 429 and 434 nm.

A spectrophotometric method for the detection of carboxymyoglobin in beef drip / Enrica Droghetti; Claudia Focardi; Mila Nocentini; Giulietta Smulevich. - In: INTERNATIONAL JOURNAL OF FOOD SCIENCE & TECHNOLOGY. - ISSN 0950-5423. - STAMPA. - 48:(2013), pp. 429-436. [10.1111/j.1365-2621.2012.03205.x]

A spectrophotometric method for the detection of carboxymyoglobin in beef drip

DROGHETTI, ENRICA;SMULEVICH, GIULIETTA
2013

Abstract

A spectrophotometric method, based on the electronic absorption and second-derivative spectra of beef drip, has been developed to detect the amount of carbon monoxide bound to myoglobin in treated beef samples. The method has been validated following the criteria reported in the Eurachem guides. The limit of detection, equal to 0.14 mu m, has been evaluated analysing ten blank samples, taking into account the mean concentration and the resulting standard deviations. The accuracy of the method has been studied in terms of trueness and precision; the first is expressed as per cent recovery (always exceeding 90%) and the second as relative standard deviation. The method is easy, rapid and allows one to determine qualitatively and quantitatively the CO concentration in the meat drip, by simply measuring in the UVVis spectrum of an unknown sample the absorbance values at three specific wavelengths: 423, 429 and 434 nm.
2013
48
429
436
Enrica Droghetti; Claudia Focardi; Mila Nocentini; Giulietta Smulevich
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/822407
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact