A new graphical user interface (GUI) for preprocessing reflectance spectra, built using MATLAB and expressly designed for the ASD FieldSpec® spectroradiometer, was developed to solve problems that generally affect experimental ASD data. The GUI is characterised by an easily readable, graphic visualisation of spectra, from which the absorption band depth (ABD) can be obtained for a selected wavelength. The output format of the ASD data is a binary file with an .asd extension. The binary file, that provides a single spectrum, can be processed using a software functionality, by means of a GUI, that allows to select one or more binary files to produce a spectral library in a unique .txt file. The spectral reflectance is re-calibrated with the “convex-hull” methodology to eliminate the convex shape, which is typical of reflectance spectra. Different examples of the use of the new GUI are provided.

Two GUIs-based analysis tool for spectroradiometer data pre-processing / Garfagnoli F.; Martelloni G.; Ciampalini A.; Innocenti L.; Moretti S.. - In: EARTH SCIENCE INFORMATICS. - ISSN 1865-0473. - STAMPA. - 6(4):(2013), pp. 227-240. [10.1007/s12145-013-0124-4]

Two GUIs-based analysis tool for spectroradiometer data pre-processing

GARFAGNOLI, FRANCESCA;MARTELLONI, GIANLUCA;CIAMPALINI, ANDREA;MORETTI, SANDRO
2013

Abstract

A new graphical user interface (GUI) for preprocessing reflectance spectra, built using MATLAB and expressly designed for the ASD FieldSpec® spectroradiometer, was developed to solve problems that generally affect experimental ASD data. The GUI is characterised by an easily readable, graphic visualisation of spectra, from which the absorption band depth (ABD) can be obtained for a selected wavelength. The output format of the ASD data is a binary file with an .asd extension. The binary file, that provides a single spectrum, can be processed using a software functionality, by means of a GUI, that allows to select one or more binary files to produce a spectral library in a unique .txt file. The spectral reflectance is re-calibrated with the “convex-hull” methodology to eliminate the convex shape, which is typical of reflectance spectra. Different examples of the use of the new GUI are provided.
2013
6(4)
227
240
Garfagnoli F.; Martelloni G.; Ciampalini A.; Innocenti L.; Moretti S.
File in questo prodotto:
File Dimensione Formato  
Garfagnoli et al ESI 2013.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/826315
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact