The international standard ISO 140-5 for the measurement of the sound insulation of build-ing façades will soon be replaced by the new standard ISO 16283-3. This revision includes the procedures for measurements at low frequencies down to 50 Hz. The uncertainty of façade sound insulation, in particular at low frequencies, was evaluated by a Round Robin Test, conducted in a full-scale experimental building at ITC-CNR. Each of the 10 teams in-volved in the RRT replicated the tests 5 times, for a total of 50 measurements. The different measurement positions inside the receiving room are compared. In particular, all the teams involved in the RRT assessed corner and center room positions; their energy average values according to ISO 16283-1 are considered and the relative uncertainty in terms of repeatability and in situ reproducibility standard deviations are compared with the ones measured and calculated following the ISO 140-5.

Uncertainty of façade sound insulation measurements obtained by a round robin test: the influence of the low frequencies extension / Scrosati, Chiara; Scamoni, Fabio; Asdrubali, Francesco; D’Alessandro, Francesco; Moretti, Elisa; Astolfi, Arianna; Barbaresi, Luca; Cellai, Gianfranco; Secchi, Simone; Bella, Antonino Di; Pontarollo, Chiara Martina; Fausti, Patrizio; Prato, Andrea; Schenone, Corrado; Zambon, Giovanni; Angelini, Fabio. - CD-ROM. - (2015), pp. 1-8. (Intervento presentato al convegno 22nd International Congress on Sound and Vibration tenutosi a Florence, Italy nel 12 – 16 July 2015).

Uncertainty of façade sound insulation measurements obtained by a round robin test: the influence of the low frequencies extension

CELLAI, GIANFRANCO;SECCHI, SIMONE;
2015

Abstract

The international standard ISO 140-5 for the measurement of the sound insulation of build-ing façades will soon be replaced by the new standard ISO 16283-3. This revision includes the procedures for measurements at low frequencies down to 50 Hz. The uncertainty of façade sound insulation, in particular at low frequencies, was evaluated by a Round Robin Test, conducted in a full-scale experimental building at ITC-CNR. Each of the 10 teams in-volved in the RRT replicated the tests 5 times, for a total of 50 measurements. The different measurement positions inside the receiving room are compared. In particular, all the teams involved in the RRT assessed corner and center room positions; their energy average values according to ISO 16283-1 are considered and the relative uncertainty in terms of repeatability and in situ reproducibility standard deviations are compared with the ones measured and calculated following the ISO 140-5.
2015
Proceedings of the 22nd International Congress on Sound and Vibration
22nd International Congress on Sound and Vibration
Florence, Italy
12 – 16 July 2015
Scrosati, Chiara; Scamoni, Fabio; Asdrubali, Francesco; D’Alessandro, Francesco; Moretti, Elisa; Astolfi, Arianna; Barbaresi, Luca; Cellai, Gianfranco...espandi
File in questo prodotto:
File Dimensione Formato  
Scrosati_RRT_ICSV22_514.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 305.73 kB
Formato Adobe PDF
305.73 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1004494
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 0
social impact