The sustainability of a small-scale self-consumption wood-energy chain for heat generation in central Italy was analyzed from a technical, economic and energetic point of view. A micro-chain was developed within the CRA-ING farm at Monterotondo (Rome, Italy): The purpose of this system was to produce biomass for supplying a heating plant within the CRA-ING property as a substitute for diesel fuel. A poplar short rotation coppice, established with clones AF2, AF6 and Monviso, fed the micro-chain. The rotation was biennial. The average plantation production (Mgd.m.·ha-1·year-1) was 10.2, with a maximum of 13.53 for the twin-rows AF2 and a minimum of 8.00 for the single-row Monviso. The economic assessment was based on the Net Present Value (NPV) method and the equivalent annuity cost, and found an average saving of 15.60 €·GJ-1 of heat generated by the wood chips heating system in comparison with the diesel heating system over a 10 year lifetime of the thermal power plant. The energy assessment of the poplar plantation, carried out using the Gross Energy Requirements method, reported an energy output/input ratio of 12.3. The energy output/input ratio of the whole micro-chain was 4.5.

Sustainability assessment of a self-consumption wood-energy chain on small scale for heat generation in central Italy / Verani, Stefano; Sperandio, Giulio; Picchio, Rodolfo; Marchi, Enrico; Costa, Corrado. - In: ENERGIES. - ISSN 1996-1073. - STAMPA. - 8:(2015), pp. 5182-5197. [10.3390/en8065182]

Sustainability assessment of a self-consumption wood-energy chain on small scale for heat generation in central Italy

MARCHI, ENRICO;
2015

Abstract

The sustainability of a small-scale self-consumption wood-energy chain for heat generation in central Italy was analyzed from a technical, economic and energetic point of view. A micro-chain was developed within the CRA-ING farm at Monterotondo (Rome, Italy): The purpose of this system was to produce biomass for supplying a heating plant within the CRA-ING property as a substitute for diesel fuel. A poplar short rotation coppice, established with clones AF2, AF6 and Monviso, fed the micro-chain. The rotation was biennial. The average plantation production (Mgd.m.·ha-1·year-1) was 10.2, with a maximum of 13.53 for the twin-rows AF2 and a minimum of 8.00 for the single-row Monviso. The economic assessment was based on the Net Present Value (NPV) method and the equivalent annuity cost, and found an average saving of 15.60 €·GJ-1 of heat generated by the wood chips heating system in comparison with the diesel heating system over a 10 year lifetime of the thermal power plant. The energy assessment of the poplar plantation, carried out using the Gross Energy Requirements method, reported an energy output/input ratio of 12.3. The energy output/input ratio of the whole micro-chain was 4.5.
2015
8
5182
5197
Verani, Stefano; Sperandio, Giulio; Picchio, Rodolfo; Marchi, Enrico; Costa, Corrado
File in questo prodotto:
File Dimensione Formato  
energies-08-05182.pdf

accesso aperto

Descrizione: Energies
Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 303.34 kB
Formato Adobe PDF
303.34 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1006276
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
social impact