PIXE and ICP-AES techniques are largely used in atmospheric aerosol studies. Since PIXE is able to provide the total elemental concentrations, while ICP-AES results depend on the extraction conditions, parallel PIXE and ICP-AES measurements of Fe, Al, Cu, Pb, Mn, Cr, Ni, V, As on PM10 and PM2.5 samples were compared. Two extraction procedures were applied to samples from 5 sites at different anthropization level in Italy: a "weak" extraction (HNO3 at pH = 1.5) and a "strong" extraction (micro-wave oven in HNO3 and H2O2 - following EU rules).

A comparison between PIXE and ICP-AES measurements of metals in aerosol particulate collected in urban and marine sites in Italy / Traversi, R.; Becagli, S.; Calzolai, G.; Chiari, M.; Giannoni, M.; Lucarelli, F; Nava, S.; Rugi, F.; Severi, M.; Udisti, R.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - STAMPA. - 318:(2014), pp. 130-134. [10.1016/j.nimb.2013.05.102]

A comparison between PIXE and ICP-AES measurements of metals in aerosol particulate collected in urban and marine sites in Italy

TRAVERSI, RITA;BECAGLI, SILVIA;CALZOLAI, GIULIA;CHIARI, MASSIMO;GIANNONI, MARTINA;LUCARELLI, FRANCO;NAVA, SILVIA;RUGI, FRANCESCO;SEVERI, MIRKO;UDISTI, ROBERTO
2014

Abstract

PIXE and ICP-AES techniques are largely used in atmospheric aerosol studies. Since PIXE is able to provide the total elemental concentrations, while ICP-AES results depend on the extraction conditions, parallel PIXE and ICP-AES measurements of Fe, Al, Cu, Pb, Mn, Cr, Ni, V, As on PM10 and PM2.5 samples were compared. Two extraction procedures were applied to samples from 5 sites at different anthropization level in Italy: a "weak" extraction (HNO3 at pH = 1.5) and a "strong" extraction (micro-wave oven in HNO3 and H2O2 - following EU rules).
2014
318
130
134
Traversi, R.; Becagli, S.; Calzolai, G.; Chiari, M.; Giannoni, M.; Lucarelli, F; Nava, S.; Rugi, F.; Severi, M.; Udisti, R.
File in questo prodotto:
File Dimensione Formato  
A comparison between PIXE and ICP AES measurements of metals in aerosol particulate collected in urban and marine sites in Italy.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.09 MB
Formato Adobe PDF
1.09 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.