PURPOSE: The aim of our study was to evaluate the usefulness of the four-dimensional computed tomography (4DCT) in accelerated partial breast irradiation (aPBI) planning. MATERIALS AND METHODS: At our Institute, we have been treating the index quadrant with external intensity-modulated radiation therapy in a phase III trial. For this study, we selected a sample of 10 patients with right- or left-sided breast cancer and surgical clips at the excision site. Contouring of the target was performed both using three-dimensional computed tomography (3DCT) and 4DCT imaging. On both 3DCT and 4DCT, we recorded the clinical target volume (CTV) and the planning target volume (PTV) and the coordinates of the PTV centroid. We calculated the treatment plans, according to our protocol, using the contours drawn on the 3DCT and 4DCT and evaluated target coverage and sparing of organs at risk (OAR). RESULTS: Median age of the patients was 63.5 years (range 52-75). The comparison between the 3DCT and 4DCT PTV volumes was not statistically significant (p = 0.79). Concerning centroid coordinates, the average absolute differences were 0.1 mm in the latero-lateral, 0.7 mm in the antero-posterior and 0.3 mm in the supero-inferior direction. No statistically significant differences were observed both in PTV coverage and OAR sparing; the 4D PTV contour is adequately covered when the plan based on the 3D contours is used. Target coverage was reduced on average by 1 % and no statistically significant difference was observed (p = 0.93). CONCLUSIONS: In our experience, no significant differences between PTV volumes, PTV coverage, OAR sparing and centroid position are evidenced when comparing 3DCT and 4DCT plans. Conventional 3DCT-based planning is adequate for aPBI.

Four-dimensional computed tomography in accelerated partial breast irradiation planning: single series from a phase III trial / Meattini, Icro; Marrazzo, Livia; Zani, Margherita; Paiar, Fabiola; Pallotta, Stefania; Simontacchi, Gabriele; Bucciolini, Marta; Livi, Lorenzo. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 120:(2015), pp. 1078-1082. [10.1007/s11547-015-0541-1]

Four-dimensional computed tomography in accelerated partial breast irradiation planning: single series from a phase III trial

MEATTINI, ICRO;MARRAZZO, LIVIA;ZANI, MARGHERITA;PAIAR, FABIOLA;PALLOTTA, STEFANIA;BUCCIOLINI, MARTA;LIVI, LORENZO
2015

Abstract

PURPOSE: The aim of our study was to evaluate the usefulness of the four-dimensional computed tomography (4DCT) in accelerated partial breast irradiation (aPBI) planning. MATERIALS AND METHODS: At our Institute, we have been treating the index quadrant with external intensity-modulated radiation therapy in a phase III trial. For this study, we selected a sample of 10 patients with right- or left-sided breast cancer and surgical clips at the excision site. Contouring of the target was performed both using three-dimensional computed tomography (3DCT) and 4DCT imaging. On both 3DCT and 4DCT, we recorded the clinical target volume (CTV) and the planning target volume (PTV) and the coordinates of the PTV centroid. We calculated the treatment plans, according to our protocol, using the contours drawn on the 3DCT and 4DCT and evaluated target coverage and sparing of organs at risk (OAR). RESULTS: Median age of the patients was 63.5 years (range 52-75). The comparison between the 3DCT and 4DCT PTV volumes was not statistically significant (p = 0.79). Concerning centroid coordinates, the average absolute differences were 0.1 mm in the latero-lateral, 0.7 mm in the antero-posterior and 0.3 mm in the supero-inferior direction. No statistically significant differences were observed both in PTV coverage and OAR sparing; the 4D PTV contour is adequately covered when the plan based on the 3D contours is used. Target coverage was reduced on average by 1 % and no statistically significant difference was observed (p = 0.93). CONCLUSIONS: In our experience, no significant differences between PTV volumes, PTV coverage, OAR sparing and centroid position are evidenced when comparing 3DCT and 4DCT plans. Conventional 3DCT-based planning is adequate for aPBI.
2015
120
1078
1082
Meattini, Icro; Marrazzo, Livia; Zani, Margherita; Paiar, Fabiola; Pallotta, Stefania; Simontacchi, Gabriele; Bucciolini, Marta; Livi, Lorenzo
File in questo prodotto:
File Dimensione Formato  
Meattini 2015 Rad Med.pdf

Accesso chiuso

Descrizione: Paper
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 485.19 kB
Formato Adobe PDF
485.19 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1009411
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact