Abstract. In this work, we have tested the optimal estimation (OE) algorithm for the reconstruction of the optical properties of a two-layered liquid tissue phantom from time-resolved single-distance measurements. The OE allows a priori information, in particular on the range of variation of fit parameters, to be included. The purpose of the present investigations was to compare the performance of OE with the Levenberg–Marquardt method for a geometry and real experimental conditions typically used to reconstruct the optical properties of biological tissues such as muscle and brain. The absorption coefficient of the layers was varied in a range of values typical for biological tissues. The reconstructions performed demonstrate the substantial improvements achievable with the OE provided a priori information is available. We note the extreme reliability, robustness, and accuracy of the retrieved absorption coefficient of the second layer obtained with the OE that was found for up to six fit parameters, with an error in the retrieved values of less than 10%. A priori information on fit parameters and fixed forward model parameters clearly improves robustness and accuracy of the inversion procedure.

Optimal estimation reconstruction of the optical properties of a two-layered tissue phantom from time-resolved single-distance measurements / Martelli, Fabrizio; Del Bianco, Samuele; Spinelli, Lorenzo; Cavalieri, Stefano; Di Ninni, Paola; Binzoni, Tiziano; Jelzow, Alexander; Macdonald, Rainer; Wabnitz, Heidrun. - In: JOURNAL OF BIOMEDICAL OPTICS. - ISSN 1083-3668. - STAMPA. - 20:(2015), pp. 115001-115001. [10.1117/1.JBO.20.11.115001]

Optimal estimation reconstruction of the optical properties of a two-layered tissue phantom from time-resolved single-distance measurements

MARTELLI, FABRIZIO;CAVALIERI, STEFANO;DI NINNI, PAOLA;
2015

Abstract

Abstract. In this work, we have tested the optimal estimation (OE) algorithm for the reconstruction of the optical properties of a two-layered liquid tissue phantom from time-resolved single-distance measurements. The OE allows a priori information, in particular on the range of variation of fit parameters, to be included. The purpose of the present investigations was to compare the performance of OE with the Levenberg–Marquardt method for a geometry and real experimental conditions typically used to reconstruct the optical properties of biological tissues such as muscle and brain. The absorption coefficient of the layers was varied in a range of values typical for biological tissues. The reconstructions performed demonstrate the substantial improvements achievable with the OE provided a priori information is available. We note the extreme reliability, robustness, and accuracy of the retrieved absorption coefficient of the second layer obtained with the OE that was found for up to six fit parameters, with an error in the retrieved values of less than 10%. A priori information on fit parameters and fixed forward model parameters clearly improves robustness and accuracy of the inversion procedure.
2015
20
115001
115001
Martelli, Fabrizio; Del Bianco, Samuele; Spinelli, Lorenzo; Cavalieri, Stefano; Di Ninni, Paola; Binzoni, Tiziano; Jelzow, Alexander; Macdonald, Raine...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1009848
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 21
social impact