Flanking and direct structural transmission are analysed with reference to the joints of a curtain wall with lightweight plasterboard partitions. Airborne sound insulation and vibrational measurements were made in two adjacent rooms affected by the acoustic problems determined by the curtain wall joint. Traditional acoustic measurements carried out according to EN ISO 16283-1 highlight problems in sound insulation between rooms, but without any indication on different sound transmission paths through the wall. Vibrational measurements were made for every part of the system (frame columns and beams, windows’ glasses, plasterboard wall, plasterboard false ceiling, etc.) to better understand the sound transmission paths in these kinds of structures. Taking into account previous works and measurements made in this research field, different solutions for curtain wall structures are analysed and technical suggestions are given to improve airborne sound insulation between rooms separated by partitions mounted up to metal frames.

Analysis of Direct and Flanking Sound Transmission Between Rooms with Curtain Wall Facades / Martello, N. Zuccherini; Secchi, S.; Fausti, P.; Cellai, G.; Santoni, A.. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - ELETTRONICO. - 78:(2015), pp. 164-169. [10.1016/j.egypro.2015.11.133]

Analysis of Direct and Flanking Sound Transmission Between Rooms with Curtain Wall Facades

SECCHI, SIMONE;CELLAI, GIANFRANCO;
2015

Abstract

Flanking and direct structural transmission are analysed with reference to the joints of a curtain wall with lightweight plasterboard partitions. Airborne sound insulation and vibrational measurements were made in two adjacent rooms affected by the acoustic problems determined by the curtain wall joint. Traditional acoustic measurements carried out according to EN ISO 16283-1 highlight problems in sound insulation between rooms, but without any indication on different sound transmission paths through the wall. Vibrational measurements were made for every part of the system (frame columns and beams, windows’ glasses, plasterboard wall, plasterboard false ceiling, etc.) to better understand the sound transmission paths in these kinds of structures. Taking into account previous works and measurements made in this research field, different solutions for curtain wall structures are analysed and technical suggestions are given to improve airborne sound insulation between rooms separated by partitions mounted up to metal frames.
2015
78
164
169
Martello, N. Zuccherini; Secchi, S.; Fausti, P.; Cellai, G.; Santoni, A.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1876610215018652-main.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 685.84 kB
Formato Adobe PDF
685.84 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1015540
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact