Reactive power handling by distributed power generation systems (DPGS) was prevented in the past in order to avoid additional power losses in the distribution feeders, however several new national grid codes request reactive power generation/absorption by the converters of active users. Actually almost no literature is focused on power losses analysis in case of reactive current circulation from the DPGS converter point of view. In the reactive power management, it has to be considered that the amount of the power losses varies on basis of the converter topology and the related modulation strategy. In this paper an accurate power losses evaluation is provided in case of two-levels and three-levels single-phase PWM inverters in grid-connected operation. The H-Bridge converter and the Neutral Point Clamped (NPC) half-bridge converter are compared. Reactive power handling feasibility is demonstrated up to low power factors (leading and lagging) involving a very limited increase of the power losses.

Power losses analysis of two-levels and three-levels PWM inverters handling reactive power / Gervasio, F.; Mastromauro, R.A.; Liserre, M.. - ELETTRONICO. - 2015-:(2015), pp. 1123-1128. (Intervento presentato al convegno 2015 IEEE International Conference on Industrial Technology, ICIT 2015 tenutosi a esp nel 2015) [10.1109/ICIT.2015.7125248].

Power losses analysis of two-levels and three-levels PWM inverters handling reactive power

MASTROMAURO, ROSA ANNA;
2015

Abstract

Reactive power handling by distributed power generation systems (DPGS) was prevented in the past in order to avoid additional power losses in the distribution feeders, however several new national grid codes request reactive power generation/absorption by the converters of active users. Actually almost no literature is focused on power losses analysis in case of reactive current circulation from the DPGS converter point of view. In the reactive power management, it has to be considered that the amount of the power losses varies on basis of the converter topology and the related modulation strategy. In this paper an accurate power losses evaluation is provided in case of two-levels and three-levels single-phase PWM inverters in grid-connected operation. The H-Bridge converter and the Neutral Point Clamped (NPC) half-bridge converter are compared. Reactive power handling feasibility is demonstrated up to low power factors (leading and lagging) involving a very limited increase of the power losses.
2015
Proceedings of the IEEE International Conference on Industrial Technology
2015 IEEE International Conference on Industrial Technology, ICIT 2015
esp
2015
Gervasio, F.; Mastromauro, R.A.; Liserre, M.
File in questo prodotto:
File Dimensione Formato  
07125248.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1016651
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 5
social impact