Abstract Objectives The purpose of this analysis was to evaluate the correlation between atrial tachycardia (AT) or atrial fibrillation (AF) and clinical outcomes in heart failure (HF) patients implanted with a cardiac resynchronization therapy defibrillator (CRT-D). Background In HF patients, AT and AF have high prevalence and are associated with compromised hemodynamic function. Methods Forty-four Italian cardiological centers followed up 1,193 patients who received a CRT-D according to current guidelines for advanced HF, New York Heart Association functional class >= II, left ventricular ejection fraction <35%, and QRS complex >120 ms. All patients were in sinus rhythm at implant. Results During a median follow-up period of 13 months, AT/AF >10 min occurred in 361 of 1,193 (30%) patients. The composite end point (deaths or HF hospitalizations) occurred in 174 of 1,193 (14.6%). Multivariate time-dependent Cox regression analyses showed that composite end point risk was higher among patients with device-detected AT/AF (hazard ratio [HR]: 2.16, p = 0.032), New York Heart Association functional class III or IV compared with II (HR: 2.09, p = 0.002), and absence of beta-blockers (HR: 1.36, p = 0.036). Furthermore, the composite end point risk was inversely associated with left ventricular ejection fraction (HR: 1.04, p = 0.045), increasing by a factor of 4% for each 1% decrease in left ventricular ejection fraction. Conclusions In HF patients with CRT-D, device-detected AT/AF is associated with a worse prognosis. Continuous device diagnostics monitoring and Web-based alerts may inform the physician of AT/AF occurrences and identify patients at risk of cardiac deterioration or patients with suboptimal rate or rhythm control. (Italian Clinical Service Project; NCT01007474) (J Am Coll Cardiol 2011;57:167-72) (C) 2011 by the American College of Cardiology Foundation
Device-detected atrial tachyarrhythmias predict adverse outcome in real-world patients with implantable biventricular defibrillators / Santini, Massimo; Gasparini, Maurizio; Landolina, Maurizio; Lunati, Maurizio; Proclemer, Alessandro; Padeletti, Luigi; Catanzariti, Domenico; Molon, Giulio; Botto, Giovanni Luca; La Rocca, Laura; Grammatico, Andrea; Boriani, Giuseppe. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - ELETTRONICO. - 57:(2011), pp. 167-172. [10.1016/j.jacc.2010.08.624]
Device-detected atrial tachyarrhythmias predict adverse outcome in real-world patients with implantable biventricular defibrillators
PADELETTI, LUIGI;
2011
Abstract
Abstract Objectives The purpose of this analysis was to evaluate the correlation between atrial tachycardia (AT) or atrial fibrillation (AF) and clinical outcomes in heart failure (HF) patients implanted with a cardiac resynchronization therapy defibrillator (CRT-D). Background In HF patients, AT and AF have high prevalence and are associated with compromised hemodynamic function. Methods Forty-four Italian cardiological centers followed up 1,193 patients who received a CRT-D according to current guidelines for advanced HF, New York Heart Association functional class >= II, left ventricular ejection fraction <35%, and QRS complex >120 ms. All patients were in sinus rhythm at implant. Results During a median follow-up period of 13 months, AT/AF >10 min occurred in 361 of 1,193 (30%) patients. The composite end point (deaths or HF hospitalizations) occurred in 174 of 1,193 (14.6%). Multivariate time-dependent Cox regression analyses showed that composite end point risk was higher among patients with device-detected AT/AF (hazard ratio [HR]: 2.16, p = 0.032), New York Heart Association functional class III or IV compared with II (HR: 2.09, p = 0.002), and absence of beta-blockers (HR: 1.36, p = 0.036). Furthermore, the composite end point risk was inversely associated with left ventricular ejection fraction (HR: 1.04, p = 0.045), increasing by a factor of 4% for each 1% decrease in left ventricular ejection fraction. Conclusions In HF patients with CRT-D, device-detected AT/AF is associated with a worse prognosis. Continuous device diagnostics monitoring and Web-based alerts may inform the physician of AT/AF occurrences and identify patients at risk of cardiac deterioration or patients with suboptimal rate or rhythm control. (Italian Clinical Service Project; NCT01007474) (J Am Coll Cardiol 2011;57:167-72) (C) 2011 by the American College of Cardiology Foundation| File | Dimensione | Formato | |
|---|---|---|---|
|
Device-Detected Atrial Tachyarrhythmias Predict Adverse Outcome in Real-World Patients With Implantable Biventricular Defibrillators.pdf
Accesso chiuso
Descrizione: Articolo scientifico
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
291.71 kB
Formato
Adobe PDF
|
291.71 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.