Abstract: It is well known that the axial load plays an important role in the evaluation of the structural capacity of RC columns. In existing buildings this problem can be even more significant than in new ones, since the material can easily present poor mechanical properties. The paper is aimed at the investigation of the role of the axial load variation on the seismic performance of RC columns of a case-study, i.e. a doubly symmetric 4-storey RC building. The effects of the axial load variation have been checked on the first storey columns, by comparing the seismic response, measured in terms of chord rotation and shear force, with the corresponding capacity. The sensitivity of the seismic performance to the axial load is evaluated with special attention on the type of analysis adopted to determine the seismic response and on considering a wide range of values for the concrete strength. The study points out a non-negligible effect of the axial load variation on the seismic response of the case-study building, especially when combined to concrete strength variability.

Combined effects of axial load and concrete strength variation on the seismic performance of existing RC buildings / Mariani, V.; Tanganelli, • M.; Viti, • S.; De Stefano, • M.. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - STAMPA. - 14:(2016), pp. 805-819. [10.1007/s10518-015-9858-3]

Combined effects of axial load and concrete strength variation on the seismic performance of existing RC buildings

MARIANI, VALENTINA;TANGANELLI, MARCO;VITI, STEFANIA;DE STEFANO, MARIO
2016

Abstract

Abstract: It is well known that the axial load plays an important role in the evaluation of the structural capacity of RC columns. In existing buildings this problem can be even more significant than in new ones, since the material can easily present poor mechanical properties. The paper is aimed at the investigation of the role of the axial load variation on the seismic performance of RC columns of a case-study, i.e. a doubly symmetric 4-storey RC building. The effects of the axial load variation have been checked on the first storey columns, by comparing the seismic response, measured in terms of chord rotation and shear force, with the corresponding capacity. The sensitivity of the seismic performance to the axial load is evaluated with special attention on the type of analysis adopted to determine the seismic response and on considering a wide range of values for the concrete strength. The study points out a non-negligible effect of the axial load variation on the seismic response of the case-study building, especially when combined to concrete strength variability.
2016
14
805
819
Mariani, V.; Tanganelli, • M.; Viti, • S.; De Stefano, • M.
File in questo prodotto:
File Dimensione Formato  
2016_AXIAL LOAD.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 2.25 MB
Formato Adobe PDF
2.25 MB Adobe PDF   Richiedi una copia
Mariani_et_al_BEE2016_Combined_effects_of_axial_load_and_concrete_strength_variation_on_the_seismic_performance_of_existing_RC_buildings.pdf

accesso aperto

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 922.45 kB
Formato Adobe PDF
922.45 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1025517
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact