In order to evaluate seismic vulnerability of existing reinforced concrete buildings, a simplified approach is proposed to take into account the beam-column joints shear collapse. This collapse is described by a link element which is introduced between column and beam. To develop and verify this element, several comparisons have been performed with experimental results of laboratory test and numerical results obtained by a two-dimensional finite element model specifically carried out for this check.The link element uses a tri-linear moment-rotation law, compatible with standard Italian and European codes, whose features can be estimated by limited structural and geometrical information, which is a typical situation on older existing structures, and by standard code recommendations.In order to give a preliminary evaluation of the seismic capacity for existing R.C. frames, taking into account the beam-column joints behaviour, this link element has been introduced in a one-dimensional model of bearing structure of the Unit N.1 of the Santa Maria Annunziata Hospital in Florence (Italy) and pushover analyses have been carried out.

Seismic vulnerability of existing R.C. buildings: A simplified numerical model to analyse the influence of the beam-column joints collapse / Borghini A., Gusella F., Vignoli A.. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - STAMPA. - 121:(2016), pp. 19-29. [10.1016/j.engstruct.2016.04.045]

Seismic vulnerability of existing R.C. buildings: A simplified numerical model to analyse the influence of the beam-column joints collapse

BORGHINI, ANDREA;GUSELLA, FEDERICO;VIGNOLI, ANDREA
2016

Abstract

In order to evaluate seismic vulnerability of existing reinforced concrete buildings, a simplified approach is proposed to take into account the beam-column joints shear collapse. This collapse is described by a link element which is introduced between column and beam. To develop and verify this element, several comparisons have been performed with experimental results of laboratory test and numerical results obtained by a two-dimensional finite element model specifically carried out for this check.The link element uses a tri-linear moment-rotation law, compatible with standard Italian and European codes, whose features can be estimated by limited structural and geometrical information, which is a typical situation on older existing structures, and by standard code recommendations.In order to give a preliminary evaluation of the seismic capacity for existing R.C. frames, taking into account the beam-column joints behaviour, this link element has been introduced in a one-dimensional model of bearing structure of the Unit N.1 of the Santa Maria Annunziata Hospital in Florence (Italy) and pushover analyses have been carried out.
2016
121
19
29
Borghini A., Gusella F., Vignoli A.
File in questo prodotto:
File Dimensione Formato  
2016 RI ENG-STR AB-FG-AV.pdf

Accesso chiuso

Descrizione: Articolo principale
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 2.1 MB
Formato Adobe PDF
2.1 MB Adobe PDF   Richiedi una copia
2016 RI ENG-STR AB-FG-AV.pdf

Accesso chiuso

Descrizione: Articolo principale
Dimensione 2.1 MB
Formato Unknown
2.1 MB Unknown   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1050309
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 30
social impact