The isodecyl neopentanoate is an ingredient used in the cosmetic industry to prepare a nipple fissure balm.We report on 12 newborns that showed elevated C5-acylcarnitine levels upon newborn screening following treatment with balm. The first 3 neonates were immediately recalled for confirmatory tests and resulted negative for both isovaleric acidemia and short/branched chain acyl-CoA dehydrogenase deficiency. In the other 9 cases, the immediate recall was avoided by applying a new second-tier test able to confirm the presence of pivaloylcarnitine. The concentration of C5-acylcarnitine was measured in the days following the suspension of balm application. Abnormal concentrations of C5-acylcarnitine did not seem to be associated with free carnitine deficiency, probably due to the short time of exposure. A direct correlation between balm ingestion and the elevation in pivaloylcarnitine has been demonstrated in 10 adult volunteers. The commercial balm containing a pivalic acid derivative is causal of false-positive results during newborn screening, and it could have the potential to cause secondary carnitine deficiency when used chronically.
Reducing the False-Positive Rate for Isovalerylcarnitine in Expanded Newborn Screening: The Application of a Second-Tier Test / Poggiali, S.; Ombrone, D.; Forni, G.; Malvagia, S.; Funghini, S.; Mura, M.; Pasquini, E.; Santoro, L.; Bellavia, V.; Granata, O. M.; Castana, C.; Mcgreevy, K. S.; Aronica, T. S.; la Marca, G.. - In: JOURNAL OF INBORN ERRORS OF METABOLISM AND SCREENING. - STAMPA. - 4:(2016), pp. 1-7. [10.1177/2326409816661355]
Reducing the False-Positive Rate for Isovalerylcarnitine in Expanded Newborn Screening: The Application of a Second-Tier Test
OMBRONE, DANIELA;LA MARCA, GIANCARLO
2016
Abstract
The isodecyl neopentanoate is an ingredient used in the cosmetic industry to prepare a nipple fissure balm.We report on 12 newborns that showed elevated C5-acylcarnitine levels upon newborn screening following treatment with balm. The first 3 neonates were immediately recalled for confirmatory tests and resulted negative for both isovaleric acidemia and short/branched chain acyl-CoA dehydrogenase deficiency. In the other 9 cases, the immediate recall was avoided by applying a new second-tier test able to confirm the presence of pivaloylcarnitine. The concentration of C5-acylcarnitine was measured in the days following the suspension of balm application. Abnormal concentrations of C5-acylcarnitine did not seem to be associated with free carnitine deficiency, probably due to the short time of exposure. A direct correlation between balm ingestion and the elevation in pivaloylcarnitine has been demonstrated in 10 adult volunteers. The commercial balm containing a pivalic acid derivative is causal of false-positive results during newborn screening, and it could have the potential to cause secondary carnitine deficiency when used chronically.File | Dimensione | Formato | |
---|---|---|---|
FPC5.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
598.43 kB
Formato
Adobe PDF
|
598.43 kB | Adobe PDF |