2-Chloroacetophenone (CA) is widely used as tear gas by law-enforcement agents, and by civilians for personal protection. Crimes involving robbery and rape using tear gas sprays have recently increased. Experimental and in-field evaluations have been performed to validate use of solid-phase microextraction (SPME) with a porous fiber for sampling and analysis of CA in air before analysis by fast gas chromatography-mass spectrometry equipped with a new device called a multi-fiber system. CA vapor was generated by use of a syringe pump in a dynamic system in which temperature, relative humidity, and air velocity were monitored. The theoretical sampling rate for time-weighted average and rapid-SPME were, furthermore, estimated by use of the Fuller-Schettler-Giddings diffusion coefficient and the theory of heat transfer, respectively, and were in accordance with experimental values. Concentrations of CA were analyzed in a military store containing tear gas canisters, to evaluate the risk. The results obtained in this field study showed values ranging from 0.206 to 2.46 mg m -3

Analysis of 2-Chloroacetophenone in air by multi-fiber solid-phase microextraction and fast gas chromatography-mass spectrometry / Pacenti, M; Dugheri, S.; Gagliano-Candela, R.; Strisciullo, G.; Franchi, E.; Degli Esposti, F.; Perchiazzi, N.; Boccalon, P.; Arcangeli, G.; Cupelli, V.. - In: ACTA CHROMATOGRAPHICA. - ISSN 1233-2356. - STAMPA. - 21:(2009), pp. 379-397. [10.1556/AChrom.21.2009.3.3]

Analysis of 2-Chloroacetophenone in air by multi-fiber solid-phase microextraction and fast gas chromatography-mass spectrometry

ARCANGELI, GIULIO;CUPELLI, VINCENZO
2009

Abstract

2-Chloroacetophenone (CA) is widely used as tear gas by law-enforcement agents, and by civilians for personal protection. Crimes involving robbery and rape using tear gas sprays have recently increased. Experimental and in-field evaluations have been performed to validate use of solid-phase microextraction (SPME) with a porous fiber for sampling and analysis of CA in air before analysis by fast gas chromatography-mass spectrometry equipped with a new device called a multi-fiber system. CA vapor was generated by use of a syringe pump in a dynamic system in which temperature, relative humidity, and air velocity were monitored. The theoretical sampling rate for time-weighted average and rapid-SPME were, furthermore, estimated by use of the Fuller-Schettler-Giddings diffusion coefficient and the theory of heat transfer, respectively, and were in accordance with experimental values. Concentrations of CA were analyzed in a military store containing tear gas canisters, to evaluate the risk. The results obtained in this field study showed values ranging from 0.206 to 2.46 mg m -3
2009
21
379
397
Pacenti, M; Dugheri, S.; Gagliano-Candela, R.; Strisciullo, G.; Franchi, E.; Degli Esposti, F.; Perchiazzi, N.; Boccalon, P.; Arcangeli, G.; Cupelli, ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1077484
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 17
social impact