In this paper, we reported the development of a micro-flow label-free impedimetric biosensor based on the use of thin-film interdigitated gold array microelectrodes (IDA) for the detection of carbohydrate antigen 125 (CA125). The immunosensor is developed through the electropolymerization of anthranilic acid (AA) on the surface of IDA electrodes followed by the covalent attachment of anti-CA125 monoclonal antibody. CA125 protein affinity reaction was then evaluated by means of electrochemical impedance spectroscopy (EIS). The sensor was characterized by electrochemical techniques and scanning electron microscopy (SEM). Using the optimized experimental conditions, the developed immunosensor showed a good analytical performance for CA125 detection from 0 to 100 U/mL with estimated limit of detection (LOD = 3Sblank/Slope) of 7 U/mL.

Micro-flow Immunosensor Based on Thin-film Interdigitated Gold Array Microelectrodes for Cancer Biomarker Detection / Ravalli, Andrea; Lozzi, Luca; Marrazza Giovanna. - In: CURRENT DRUG DELIVERY. - ISSN 1567-2018. - STAMPA. - 13:(2016), pp. 400-408.

Micro-flow Immunosensor Based on Thin-film Interdigitated Gold Array Microelectrodes for Cancer Biomarker Detection

Ravalli, Andrea;Marrazza Giovanna
2016

Abstract

In this paper, we reported the development of a micro-flow label-free impedimetric biosensor based on the use of thin-film interdigitated gold array microelectrodes (IDA) for the detection of carbohydrate antigen 125 (CA125). The immunosensor is developed through the electropolymerization of anthranilic acid (AA) on the surface of IDA electrodes followed by the covalent attachment of anti-CA125 monoclonal antibody. CA125 protein affinity reaction was then evaluated by means of electrochemical impedance spectroscopy (EIS). The sensor was characterized by electrochemical techniques and scanning electron microscopy (SEM). Using the optimized experimental conditions, the developed immunosensor showed a good analytical performance for CA125 detection from 0 to 100 U/mL with estimated limit of detection (LOD = 3Sblank/Slope) of 7 U/mL.
2016
13
400
408
Ravalli, Andrea; Lozzi, Luca; Marrazza Giovanna
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1080001
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact