Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch or resist voluntary movements of fingers or wrist. These simple systems are limited by the impossibility of modulating the mechanical stiffness. This limitation does not allow for customizations and real-time control of the training exercise, which would improve the rehabilitation efficacy. To overcome this limitation, ‘active’ orthoses equipped with devices that allow for electrical control of the mechanical stiffness are needed. Here, we report on a solution that relies on compact and light-weight electroactive elastic transducers that replace the passive elastic components. We developed a variable-stiffness transducer made of dielectric elastomers, as the most performing types of electromechanically active polymers. The transducer was manufactured with a silicone film and tested with a purposely-developed stiffness control strategy that allowed for electrical modulations of the force-elongation response. Results showed that the proposed new technology is a promising and viable solution to develop electrically controllable dynamic hand orthoses for hand rehabilitation.

Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers / Carpi, Federico; Frediani, Gabriele; Gerboni, Carlo; Gemignani, Jessica; De Rossi, Danilo. - In: MEDICAL ENGINEERING & PHYSICS. - ISSN 1350-4533. - ELETTRONICO. - 36:(2014), pp. 205-211. [10.1016/j.medengphy.2013.10.015]

Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers

CARPI, FEDERICO;
2014

Abstract

Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch or resist voluntary movements of fingers or wrist. These simple systems are limited by the impossibility of modulating the mechanical stiffness. This limitation does not allow for customizations and real-time control of the training exercise, which would improve the rehabilitation efficacy. To overcome this limitation, ‘active’ orthoses equipped with devices that allow for electrical control of the mechanical stiffness are needed. Here, we report on a solution that relies on compact and light-weight electroactive elastic transducers that replace the passive elastic components. We developed a variable-stiffness transducer made of dielectric elastomers, as the most performing types of electromechanically active polymers. The transducer was manufactured with a silicone film and tested with a purposely-developed stiffness control strategy that allowed for electrical modulations of the force-elongation response. Results showed that the proposed new technology is a promising and viable solution to develop electrically controllable dynamic hand orthoses for hand rehabilitation.
2014
36
205
211
Carpi, Federico; Frediani, Gabriele; Gerboni, Carlo; Gemignani, Jessica; De Rossi, Danilo
File in questo prodotto:
File Dimensione Formato  
Enabling variable-stiffness hand rehabilitation orthoses with DET.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.39 MB
Formato Adobe PDF
1.39 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1085507
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 51
social impact