This Letter presents a novel approach to develop haptic displays of motility of organs and compliance of tissues, aimed at combining structural simplicity with realistic appearance and consistence. The dielectric elastomer actuation technology was used to mimic mechanical passive properties and electromechanical active functions of tissues, by means of electro-responsive elastomeric devices. Proof-of-concept displays were conceived for medical training in cardiology and surgical force feedback in minimally invasive procedures. In particular, prototype displays of cardiac contractility, pulsatile blood pressure and compliance of soft tissues were manufactured with silicone and acrylic elastomers. Preliminary physical and psychophysical tests suggested the feasibility of the considered approach, while emphasizing required improvements.

Electroactive elastomeric haptic displays of organ motility and tissue compliance for medical training and surgical force feedback / Carpi, Federico; Frediani, Gabriele; De Rossi, Danilo. - In: IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING. - ISSN 0018-9294. - ELETTRONICO. - 56:(2009), pp. 2327-2330. [10.1109/TBME.2009.2024691]

Electroactive elastomeric haptic displays of organ motility and tissue compliance for medical training and surgical force feedback

CARPI, FEDERICO;
2009

Abstract

This Letter presents a novel approach to develop haptic displays of motility of organs and compliance of tissues, aimed at combining structural simplicity with realistic appearance and consistence. The dielectric elastomer actuation technology was used to mimic mechanical passive properties and electromechanical active functions of tissues, by means of electro-responsive elastomeric devices. Proof-of-concept displays were conceived for medical training in cardiology and surgical force feedback in minimally invasive procedures. In particular, prototype displays of cardiac contractility, pulsatile blood pressure and compliance of soft tissues were manufactured with silicone and acrylic elastomers. Preliminary physical and psychophysical tests suggested the feasibility of the considered approach, while emphasizing required improvements.
2009
56
2327
2330
Carpi, Federico; Frediani, Gabriele; De Rossi, Danilo
File in questo prodotto:
File Dimensione Formato  
Electroactive elastomeric haptic displays etc.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 365.04 kB
Formato Adobe PDF
365.04 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1085617
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 31
social impact