After almost three years in orbit, the statistic collected by PAMELA detector for what concern nuclei events from cosmic rays is sufficiently relevant to allow a systematic study of such a component. For this scope charge reconstruction from Time-of-Flight system, calorimeter and magnetic spectrometer is used, with different combinations, in order to cover the widest range of inspection in energy and atomic number permitted by the characteristics of the detector. Some results for performances, goals and limits from the different sub-detectors will be presented.
PAMELA sub-detectors capability in identifying nuclei: Status of art and perspectives / Carbone, R.; Adriani, O.; Barbarino, G.C.; Bazilevskaya, G.A.; Bellotti, R.; Boezio, M.; Bogomolov, E.A.; Bongi, M.; Bonvicini, V.; Borisov, S.; Bottai, S.; Bruno, A.; Cafagna, F.; Campana, D.; Carlson, P.; Casolino, M.; Castellini, G.; Consiglio, L.; De Pascale, M.P.; De Santis, C.; De Simone, N.; Di Felice, V.; Galper, A.M.; Gillard, W.; Grishantseva, L.; Jerse, G.; Karelin, A.V.; Kheymits, M.D.; Koldashov, S.V.; Krutkov, S.Y.; Kvashnin, A.N.; Leonov, A.; Malakhov, V.; Marcelli, L.; Mayorov, A.G.; Menn, W.; Mikhailov, V.V.; Mocchiutti, E.; Monaco, A.; Mori, N.; Nikonov, N.; Osteria, G.; Palma, F.; Papini, P.; Pearce, M.; Picozza, P.; Pizzolotto, C.; Ricci, M.; Ricciarini, S.B.; Rossetto, L.; Sarkar, R.; Simon, M.; Sparvoli, R.; Spillantini, P.; Stozhkov, Y.I.; Vacchi, A.; Vannuccini, E.; Vasilyev, G.; Voronov, S.A.; Yurkin, Y.T.; Wu, J.; Zampa, G.; Zampa, N.; Zverev, V.G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - ELETTRONICO. - 630:(2011), pp. 234-237. [10.1016/j.nima.2010.06.074]
PAMELA sub-detectors capability in identifying nuclei: Status of art and perspectives
ADRIANI, OSCAR;BONGI, MASSIMO;
2011
Abstract
After almost three years in orbit, the statistic collected by PAMELA detector for what concern nuclei events from cosmic rays is sufficiently relevant to allow a systematic study of such a component. For this scope charge reconstruction from Time-of-Flight system, calorimeter and magnetic spectrometer is used, with different combinations, in order to cover the widest range of inspection in energy and atomic number permitted by the characteristics of the detector. Some results for performances, goals and limits from the different sub-detectors will be presented.I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



