Abstract. A modern heritage reinforced concrete (R/C) swimming pool building designed by Pier Luigi Nervi is examined in this paper. The distinguishing feature of the structure is represented by the barrel vault-shaped roof, constituted by prefab R/C curved beams with smoothed-V wavy section, typical of the internationally recognized Nervi’s style. The R/C columns and beams supporting the roof and the lateral aisles — originally designed for gravitational loads only and pursuing a minimal size philosophy with respect to the calculated stress states — have very small cross sections. As a consequence, the seismic performance assessment analysis carried out in this study shows general unsafe response conditions of these members. In order to substantially improve the seismic response capacity of the building, as well as to avoid any intrusive intervention on the exposed structural elements, an advanced retrofit strategy is proposed, which consists in the installation of a base isolation system incorporating double curved surface slider devices at the feet of all columns and below the pool tank.

Seismic assessment and base isolation retrofit of a modern heritage R/C swimming pool / Stefano, Sorace; Gloria, Terenzi. - CD-ROM. - 1:(2017), pp. 1-11. (Intervento presentato al convegno Proceedings of 3rd International Conference on Protection of Historical Constructions PROHITECH 2017 tenutosi a Lisbon nel 12-15 July).

Seismic assessment and base isolation retrofit of a modern heritage R/C swimming pool

TERENZI, GLORIA
2017

Abstract

Abstract. A modern heritage reinforced concrete (R/C) swimming pool building designed by Pier Luigi Nervi is examined in this paper. The distinguishing feature of the structure is represented by the barrel vault-shaped roof, constituted by prefab R/C curved beams with smoothed-V wavy section, typical of the internationally recognized Nervi’s style. The R/C columns and beams supporting the roof and the lateral aisles — originally designed for gravitational loads only and pursuing a minimal size philosophy with respect to the calculated stress states — have very small cross sections. As a consequence, the seismic performance assessment analysis carried out in this study shows general unsafe response conditions of these members. In order to substantially improve the seismic response capacity of the building, as well as to avoid any intrusive intervention on the exposed structural elements, an advanced retrofit strategy is proposed, which consists in the installation of a base isolation system incorporating double curved surface slider devices at the feet of all columns and below the pool tank.
2017
Proceedings of 3rd International Conference on Protection of Historical Constructions PROHITECH 2017
Proceedings of 3rd International Conference on Protection of Historical Constructions PROHITECH 2017
Lisbon
12-15 July
Stefano, Sorace; Gloria, Terenzi
File in questo prodotto:
File Dimensione Formato  
PROHITECH2017_Full_Paper_153.pdf

Accesso chiuso

Descrizione: Articolo pubblicato in formato elettronico
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1091269
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact