Purpose: Thorough this experimental study, the physic features of a modified 23-gauge vitrectomy probe were evaluated in vitro. Methods: A modified vitrectomy probe to increase vitreous outflow rate with a smalldiameter probe, that also minimized tractional forces on the retina, was created and tested. The “new” probe was created by drilling an opening into the inner duct of a traditional 23- gauge probe with electrochemical or electrodischarge micromachining. Both vitreous outflow and tractional forces on the retina were examined using experimental models of vitreous surgery. Results: The additional opening allowed the modified probe to have a cutting rate of 5,000 cuts per minute, while sustaining an outflow approximately 45% higher than in conventional 23-gauge probes. The modified probe performed two cutting actions per cycle, not one, as in standard probes. Because tractional force is influenced by cutting rate, retinal forces were 2.2 times lower than those observed with traditional cutters. Conclusion: The modified probe could be useful in vitreoretinal surgery. It allows for faster vitreous removal while minimizing tractional forces on the retina.

Effects of a modified vitrectomy probe in small-gauge vitrectomy / Rizzo, Stanislao; Fantoni, Gualtiero; De Santis, Giovanni; Lue, Jaw Chyng Lormen; Ciampi, Jonathan; Palla, Michele; Genovesi Ebert, Federica; Savastano, Alfonso; De Maria, Carmelo; Vozzi, Giovanni; Fernandes, Rodrigo A. Brant; Faraldi, Francesco; Criscenti, Giuseppe. - In: RETINA. - ISSN 0275-004X. - STAMPA. - 37:(2017), pp. 1765-1774. [10.1097/IAE.0000000000001411]

Effects of a modified vitrectomy probe in small-gauge vitrectomy

RIZZO, STANISLAO;Savastano, Alfonso;FARALDI, FRANCESCO;
2017

Abstract

Purpose: Thorough this experimental study, the physic features of a modified 23-gauge vitrectomy probe were evaluated in vitro. Methods: A modified vitrectomy probe to increase vitreous outflow rate with a smalldiameter probe, that also minimized tractional forces on the retina, was created and tested. The “new” probe was created by drilling an opening into the inner duct of a traditional 23- gauge probe with electrochemical or electrodischarge micromachining. Both vitreous outflow and tractional forces on the retina were examined using experimental models of vitreous surgery. Results: The additional opening allowed the modified probe to have a cutting rate of 5,000 cuts per minute, while sustaining an outflow approximately 45% higher than in conventional 23-gauge probes. The modified probe performed two cutting actions per cycle, not one, as in standard probes. Because tractional force is influenced by cutting rate, retinal forces were 2.2 times lower than those observed with traditional cutters. Conclusion: The modified probe could be useful in vitreoretinal surgery. It allows for faster vitreous removal while minimizing tractional forces on the retina.
2017
37
1765
1774
Rizzo, Stanislao; Fantoni, Gualtiero; De Santis, Giovanni; Lue, Jaw Chyng Lormen; Ciampi, Jonathan; Palla, Michele; Genovesi Ebert, Federica; Savastan...espandi
File in questo prodotto:
File Dimensione Formato  
5_ Effect of modified vitrectomy PROBE.pdf

accesso aperto

Descrizione: full article
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 881.65 kB
Formato Adobe PDF
881.65 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1094915
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact