Contactless techniques are of increasing clinical interest as they can provide advantages in terms of comfort and safety of the patient with respect to sensor-based methods. Therefore, they are particularly well suited for vulnerable patients such as newborns. Specifically the acoustical analysis of the infant cry is a contactless approach to assist the clinical specialist in the detection of abnormalities in infants with possible neurological disorders. Along with the perceptual analysis, the automated analysis of infant cry is usually performed through software tools that however might not be devoted to this specific signal. The newborn cry is a signal extremely difficult to analyze with standard techniques due to its quasi-stationarity and to very high range of frequencies of interest. Therefore software tools should be specifically set and used with caution. To address this issue three methods are tested and compared, one freely available and other two specifically built using different approaches: autoregressive adaptive models and wavelets. The three methods are compared using synthetic signals coming from a synthesizer developed for the generation of basic melodic shapes of the newborn cry. Results point out strengths and weaknesses of each method, thus suggesting their most appropriate use according to the goals of the analysis.
Testing software tools for newborn cry analysis using synthetic signals / Orlandi, S.; Bandini, A.; Fiaschi, F. F.; Manfredi, C.. - In: BIOMEDICAL SIGNAL PROCESSING AND CONTROL. - ISSN 1746-8094. - STAMPA. - 37:(2017), pp. 16-22. [10.1016/j.bspc.2016.12.012]
Testing software tools for newborn cry analysis using synthetic signals
Manfredi, C.Membro del Collaboration Group
2017
Abstract
Contactless techniques are of increasing clinical interest as they can provide advantages in terms of comfort and safety of the patient with respect to sensor-based methods. Therefore, they are particularly well suited for vulnerable patients such as newborns. Specifically the acoustical analysis of the infant cry is a contactless approach to assist the clinical specialist in the detection of abnormalities in infants with possible neurological disorders. Along with the perceptual analysis, the automated analysis of infant cry is usually performed through software tools that however might not be devoted to this specific signal. The newborn cry is a signal extremely difficult to analyze with standard techniques due to its quasi-stationarity and to very high range of frequencies of interest. Therefore software tools should be specifically set and used with caution. To address this issue three methods are tested and compared, one freely available and other two specifically built using different approaches: autoregressive adaptive models and wavelets. The three methods are compared using synthetic signals coming from a synthesizer developed for the generation of basic melodic shapes of the newborn cry. Results point out strengths and weaknesses of each method, thus suggesting their most appropriate use according to the goals of the analysis.File | Dimensione | Formato | |
---|---|---|---|
BSPC SI 2017.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
658.77 kB
Formato
Adobe PDF
|
658.77 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.