Abstract PURPOSE: Radiosurgery (RS) is a well-established treatment in selected patients with brain metastasis. The aim of this study is to compare the differences between CyberKnife (CK) and TomoTherapy (HT) treatment plans of RS of single brain metastasis (BM) to define when HT should be used in cases beyond Cyberknife-when both systems are readily available for the radiation oncologist. METHODS AND MATERIALS: Nineteen patients with single brain metastasis treated with CK were re-planned for radiosurgery using TomoTherapy Hi-ART system. Two planning approaches have been used for TomoTherapy plans: the classical one (HT) and the improved conformity (icHT) that produces dose distributions more similar to those of RS plans. PTV coverage, Conformity Index (CI), Paddick Conformity Index (nCI), Homogeneity Index (HI), Gradient Index (GI), and beam on time of CK, HT, and icHT plans were evaluated and compared. RESULTS: A good coverage was found for CK, HT, and icHT plans. A difference between mean HI of CK and icHT plans was observed (p = 0.007). Better dose gradients compared to both icHT and HT modalities were observed in CK plans. icHT modality showed improved mean CI respect to HT modality, similar to that obtained in CK plans. CONCLUSIONS: CK plans show higher conformity and lower GI than icHT and HT plans. TomoTherapy demonstrates the advantage of being a device capable to reach different clinical objectives depending on the different planning modality employed. CyberKnife and TomoTherapy are both optimal RS devices, the choice to use one over another has to be clinically guided.
A dosimetric comparison between CyberKnife and tomotherapy treatment plans for single brain metastasis / Greto, Daniela; Pallotta, Stefania; Masi, Laura; Talamonti, Cinzia; Marrazzo, Livia; Doro, Raffaella; Saieva, Calogero; Scoccianti, Silvia; Desideri, Isacco; Livi, Lorenzo. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - ELETTRONICO. - 122:(2017), pp. 392-397. [10.1007/s11547-017-0735-9]
A dosimetric comparison between CyberKnife and tomotherapy treatment plans for single brain metastasis
Greto, Daniela;Pallotta, Stefania;Talamonti, Cinzia;Marrazzo, Livia;Scoccianti, Silvia;Desideri, Isacco;Livi, Lorenzo
2017
Abstract
Abstract PURPOSE: Radiosurgery (RS) is a well-established treatment in selected patients with brain metastasis. The aim of this study is to compare the differences between CyberKnife (CK) and TomoTherapy (HT) treatment plans of RS of single brain metastasis (BM) to define when HT should be used in cases beyond Cyberknife-when both systems are readily available for the radiation oncologist. METHODS AND MATERIALS: Nineteen patients with single brain metastasis treated with CK were re-planned for radiosurgery using TomoTherapy Hi-ART system. Two planning approaches have been used for TomoTherapy plans: the classical one (HT) and the improved conformity (icHT) that produces dose distributions more similar to those of RS plans. PTV coverage, Conformity Index (CI), Paddick Conformity Index (nCI), Homogeneity Index (HI), Gradient Index (GI), and beam on time of CK, HT, and icHT plans were evaluated and compared. RESULTS: A good coverage was found for CK, HT, and icHT plans. A difference between mean HI of CK and icHT plans was observed (p = 0.007). Better dose gradients compared to both icHT and HT modalities were observed in CK plans. icHT modality showed improved mean CI respect to HT modality, similar to that obtained in CK plans. CONCLUSIONS: CK plans show higher conformity and lower GI than icHT and HT plans. TomoTherapy demonstrates the advantage of being a device capable to reach different clinical objectives depending on the different planning modality employed. CyberKnife and TomoTherapy are both optimal RS devices, the choice to use one over another has to be clinically guided.I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.