Measuring the thickness and the composition of precious metal thin films is a challenging task. Currently, the available techniques for thickness measurements are either destructive or need heavy assumptions on the nature of the sample, relying on information that are not always available with sufficient accuracy. In this paper we propose a new methodology based on X-ray microanalysis that can complement, with better lateral resolution, the use of X-ray Fluorescence, the most widely employed technique for measuring the thickness of electrodeposited coatings. The proposed method employs a combination of energy dispersive microanalysis spectra acquisition and Monte Carlo simulation. The effectiveness of the technique has been demonstrated by the measure of the thickness and the composition of a thin 24 kt gold electroplated film that contained small amount of nickel. Results have been validated by comparing data with those obtained by X-ray fluorescence and the scanning electron microscopy of metallographic cross-sections.

X-ray Microanalysis of Precious Metal Thin Films: Thickness and Composition Determination / Giurlani, Walter; Innocenti, Massimo; Lavacchi, Alessandro. - In: COATINGS. - ISSN 2079-6412. - ELETTRONICO. - 8:(2018), pp. 0-0. [10.3390/coatings8020084]

X-ray Microanalysis of Precious Metal Thin Films: Thickness and Composition Determination

Giurlani, Walter
;
Innocenti, Massimo;Lavacchi, Alessandro
2018

Abstract

Measuring the thickness and the composition of precious metal thin films is a challenging task. Currently, the available techniques for thickness measurements are either destructive or need heavy assumptions on the nature of the sample, relying on information that are not always available with sufficient accuracy. In this paper we propose a new methodology based on X-ray microanalysis that can complement, with better lateral resolution, the use of X-ray Fluorescence, the most widely employed technique for measuring the thickness of electrodeposited coatings. The proposed method employs a combination of energy dispersive microanalysis spectra acquisition and Monte Carlo simulation. The effectiveness of the technique has been demonstrated by the measure of the thickness and the composition of a thin 24 kt gold electroplated film that contained small amount of nickel. Results have been validated by comparing data with those obtained by X-ray fluorescence and the scanning electron microscopy of metallographic cross-sections.
2018
8
0
0
Giurlani, Walter; Innocenti, Massimo; Lavacchi, Alessandro
File in questo prodotto:
File Dimensione Formato  
coatings-08-00084-v2.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Creative commons
Dimensione 2.08 MB
Formato Adobe PDF
2.08 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1116440
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 27
social impact