A viable design criterion of supplemental damping strategies for seismic retrofit of frame structures, recently proposed by the first author (Terenzi, 2018), is applied in this paper to a school building in Florence dating back to the early 1980s. The building is composed of two portions, with reinforced concrete and steel frame structure, respectively. Similarly to several other buildings of the same period, the structure is infilled by heavy reinforced concrete panels interacting with the frame elements under horizontal loads. A careful reconstruction of the structural characteristics of the constituting members, based on the original design documentation and on-site testing campaigns, highlighted specific drawbacks in current state, related to a remarkable degration of the materials and a poor performance of several elements. The retrofit solution considered in this study consists in removing the infill panels and replacing them with a set of dissipative braces incorporating fluid viscous dampers as protective devices. The design is carried out by the sizing criterion mentioned above, targeting an elastic structural response up to the maximum considered earthquake normative level.
Verification of an energy-based design procedure for seismic retrofit of a school building / Gloria Terenzi, Iacopo Costoli, Stefano Sorace, Paolo Spinelli. - ELETTRONICO. - 11:(2018), pp. 161-168. (Intervento presentato al convegno 14th International Conference on Building Pathology and Constructions Repair, CINPAR 2018, 20-22 June 2018, Firenze, Italy tenutosi a Florence, Italy nel 20-22 June 2018) [10.1016/j.prostr.2018.11.022].
Verification of an energy-based design procedure for seismic retrofit of a school building
Gloria Terenzi
;Iacopo Costoli;Paolo Spinelli
2018
Abstract
A viable design criterion of supplemental damping strategies for seismic retrofit of frame structures, recently proposed by the first author (Terenzi, 2018), is applied in this paper to a school building in Florence dating back to the early 1980s. The building is composed of two portions, with reinforced concrete and steel frame structure, respectively. Similarly to several other buildings of the same period, the structure is infilled by heavy reinforced concrete panels interacting with the frame elements under horizontal loads. A careful reconstruction of the structural characteristics of the constituting members, based on the original design documentation and on-site testing campaigns, highlighted specific drawbacks in current state, related to a remarkable degration of the materials and a poor performance of several elements. The retrofit solution considered in this study consists in removing the infill panels and replacing them with a set of dissipative braces incorporating fluid viscous dampers as protective devices. The design is carried out by the sizing criterion mentioned above, targeting an elastic structural response up to the maximum considered earthquake normative level.File | Dimensione | Formato | |
---|---|---|---|
PROSTR_ CINPAR2018_Terenzi_Costoli_Sorace_SpinelliConvegno.pdf
Accesso chiuso
Descrizione: Articolo in preprint
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
1.46 MB
Formato
Adobe PDF
|
1.46 MB | Adobe PDF | Richiedi una copia |
Articolo pubblicato.pdf
Accesso chiuso
Descrizione: articolo pubblicato on-line
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
2.53 MB
Formato
Adobe PDF
|
2.53 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.