OBJECTIVES: We designed a pilot study to evaluate safety and feasibility of an inexpensive and simple approach to intracoronary hemodilution during primary angioplasty (PPCI) to reduce reperfusion injury. INTRODUCTION: Early revascularization in acute myocardial infarction decreases infarct size and improves outcomes. However, abrupt restoration of coronary flow results in myocardial reperfusion injury and increased final infarct size. Dilution of coronary blood during revascularization may help reduce this damage. If proved effective, such an approach would need to be simple and suitable for widespread adoption. METHODS: Ten patients presenting with STEMI underwent intracoronary dilution with room temperature Hartmann's solution delivered through the guiding catheter during primary angioplasty (PPCI). Infusion of perfusate began prior to crossing the occluded artery with the guidewire, continuing until 10 min after completion of the balloon and stenting procedure. Infusion was briefly interrupted for contrast injection and pressure monitoring. The outcome measures were safety, including intracoronary temperature reduction and volume of intracoronary perfusate infused, and technical feasibility. RESULTS: There were no significant symptomatic, hemodynamic, ECG ST/T segment or rhythm changes observed during perfusate administration. The median (interquartile range) volume of perfusate administered was 550 mL (350-725 mL) and the median intracoronary temperature reduction observed was 3.4°Celsius. Myocardial salvage was 0.54 (0.43-0.65). CONCLUSIONS: Transcatheter intracoronary hemodilution with room temperature perfusate during PPCI is feasible and appears safe. Such a strategy is simple and inexpensive, with potential to be widely applied. Further mechanistic and subsequent outcome powered studies are required to evaluate whether this strategy can reduce reperfusion injury in STEMI.

A feasibility and safety study of intracoronary hemodilution during primary coronary angioplasty in order to reduce reperfusion injury in myocardial infarction / McGarvey, Michael*; Ali, Omar; Iqbal, M. Bilal; Ilsley, Charles; Wong, Joyce; Di Mario, Carlo; Redwood, Simon; Patterson, Tiffany; Pennell, Dudley J.; Rogers, Paula; Dalby, Miles. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - ELETTRONICO. - 91:(2018), pp. 234-241. [10.1002/ccd.27136]

A feasibility and safety study of intracoronary hemodilution during primary coronary angioplasty in order to reduce reperfusion injury in myocardial infarction

Di Mario, Carlo;
2018

Abstract

OBJECTIVES: We designed a pilot study to evaluate safety and feasibility of an inexpensive and simple approach to intracoronary hemodilution during primary angioplasty (PPCI) to reduce reperfusion injury. INTRODUCTION: Early revascularization in acute myocardial infarction decreases infarct size and improves outcomes. However, abrupt restoration of coronary flow results in myocardial reperfusion injury and increased final infarct size. Dilution of coronary blood during revascularization may help reduce this damage. If proved effective, such an approach would need to be simple and suitable for widespread adoption. METHODS: Ten patients presenting with STEMI underwent intracoronary dilution with room temperature Hartmann's solution delivered through the guiding catheter during primary angioplasty (PPCI). Infusion of perfusate began prior to crossing the occluded artery with the guidewire, continuing until 10 min after completion of the balloon and stenting procedure. Infusion was briefly interrupted for contrast injection and pressure monitoring. The outcome measures were safety, including intracoronary temperature reduction and volume of intracoronary perfusate infused, and technical feasibility. RESULTS: There were no significant symptomatic, hemodynamic, ECG ST/T segment or rhythm changes observed during perfusate administration. The median (interquartile range) volume of perfusate administered was 550 mL (350-725 mL) and the median intracoronary temperature reduction observed was 3.4°Celsius. Myocardial salvage was 0.54 (0.43-0.65). CONCLUSIONS: Transcatheter intracoronary hemodilution with room temperature perfusate during PPCI is feasible and appears safe. Such a strategy is simple and inexpensive, with potential to be widely applied. Further mechanistic and subsequent outcome powered studies are required to evaluate whether this strategy can reduce reperfusion injury in STEMI.
2018
91
234
241
McGarvey, Michael*; Ali, Omar; Iqbal, M. Bilal; Ilsley, Charles; Wong, Joyce; Di Mario, Carlo; Redwood, Simon; Patterson, Tiffany; Pennell, Dudley J.;...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1135693
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact