OBJECTIVES: We sought to compare, in a prospective randomized multicenter study, the effect of adjunctive thrombectomy using X-Sizer (eV3, White Bear Lake, Minnesota) before percutaneous coronary intervention (PCI) versus conventional PCI in patients with acute myocardial infarction (AMI) for <12 h and Thrombolysis In Myocardial Infarction (TIMI) flow grade 0 to 1. The primary end point was the magnitude of ST-segment resolution after PCI. BACKGROUND: Despite a high rate of TIMI flow grade 3 achieved by PCI in patients with AMI, myocardial reperfusion remains relatively low. Distal embolization of thrombotic materials may play a major role in this setting. METHODS: We conducted a prospective, randomized, multicenter study in patients with AMI <12 h and initial TIMI flow grade 0 to 1 who were treated with primary PCI. The magnitude of ST-segment resolution 1 h after PCI was the primary end point. RESULTS: A total of 201 patients were included. Treatment groups were comparable by age (61 +/- 13 years), diabetes (22%), previous MI (8%), anterior MI (52%), onset-to-angiogram (258 +/- 173 min), and glycoprotein IIb/IIIa inhibitor use (59%). The magnitude of ST-segment resolution was greater in the X-Sizer group compared with the conventional group (7.5 vs. 4.9 mm, respectively; p = 0.033) as ST-segment resolution >50% (68% vs. 53%; p = 0.037). The occurrence of distal embolization was reduced (2% vs. 10%; p = 0.033) and TIMI flow grade 3 was obtained in 96% vs. 89%, respectively (p = 0.105). Myocardial blush grade 3 was similar (30% vs. 31%; p = NS). Six-month clinical outcome was comparable (death, 6% vs. 4% and major adverse cardiac and cerebral events, 13% vs. 13%, respectively). By multivariate analysis, independent predictors of ST-segment resolution >50% were: younger age, non-anterior MI, use of the X-Sizer, and a short time interval from symptom onset. CONCLUSIONS: Reducing thrombus burden with X-Sizer before stenting leads to better myocardial reperfusion, as illustrated by a reduced risk of distal embolization and better ST-segment resolution.

X-sizer for thrombectomy in acute myocardial infarction improves ST-segment resolution: Results of the X-sizer in AMI for negligible embolization and optimal ST resolution (X AMINE ST) trial / Lefèvre, Thierry; Garcia, Eulegio; Reimers, Bernhard; Lang, Iréne; Di Mario, Carlo; Colombo, Antonio; Neumann, Franz-Joseph; Chavarri, Mariano Valdés; Brunel, Philippe; Grube, Eberhart; Thomas, Martin; Glatt, Bernard; Ludwig, Joseph. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - ELETTRONICO. - 46:(2005), pp. 246-252. [10.1016/j.jacc.2005.04.031]

X-sizer for thrombectomy in acute myocardial infarction improves ST-segment resolution: Results of the X-sizer in AMI for negligible embolization and optimal ST resolution (X AMINE ST) trial

Di Mario, Carlo;
2005

Abstract

OBJECTIVES: We sought to compare, in a prospective randomized multicenter study, the effect of adjunctive thrombectomy using X-Sizer (eV3, White Bear Lake, Minnesota) before percutaneous coronary intervention (PCI) versus conventional PCI in patients with acute myocardial infarction (AMI) for <12 h and Thrombolysis In Myocardial Infarction (TIMI) flow grade 0 to 1. The primary end point was the magnitude of ST-segment resolution after PCI. BACKGROUND: Despite a high rate of TIMI flow grade 3 achieved by PCI in patients with AMI, myocardial reperfusion remains relatively low. Distal embolization of thrombotic materials may play a major role in this setting. METHODS: We conducted a prospective, randomized, multicenter study in patients with AMI <12 h and initial TIMI flow grade 0 to 1 who were treated with primary PCI. The magnitude of ST-segment resolution 1 h after PCI was the primary end point. RESULTS: A total of 201 patients were included. Treatment groups were comparable by age (61 +/- 13 years), diabetes (22%), previous MI (8%), anterior MI (52%), onset-to-angiogram (258 +/- 173 min), and glycoprotein IIb/IIIa inhibitor use (59%). The magnitude of ST-segment resolution was greater in the X-Sizer group compared with the conventional group (7.5 vs. 4.9 mm, respectively; p = 0.033) as ST-segment resolution >50% (68% vs. 53%; p = 0.037). The occurrence of distal embolization was reduced (2% vs. 10%; p = 0.033) and TIMI flow grade 3 was obtained in 96% vs. 89%, respectively (p = 0.105). Myocardial blush grade 3 was similar (30% vs. 31%; p = NS). Six-month clinical outcome was comparable (death, 6% vs. 4% and major adverse cardiac and cerebral events, 13% vs. 13%, respectively). By multivariate analysis, independent predictors of ST-segment resolution >50% were: younger age, non-anterior MI, use of the X-Sizer, and a short time interval from symptom onset. CONCLUSIONS: Reducing thrombus burden with X-Sizer before stenting leads to better myocardial reperfusion, as illustrated by a reduced risk of distal embolization and better ST-segment resolution.
2005
46
246
252
Lefèvre, Thierry; Garcia, Eulegio; Reimers, Bernhard; Lang, Iréne; Di Mario, Carlo; Colombo, Antonio; Neumann, Franz-Joseph; Chavarri, Mariano Valdés;...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1135773
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 190
  • ???jsp.display-item.citation.isi??? 141
social impact