Bioresorbable scaffolds have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by persistent metallic foreign body. Early clinical studies using the first commercially available drug-eluting bioresorbable vascular scaffold (BVS) reported very promising safety and efficacy outcomes, comparable to best-in-class second-generation drug-eluting metal stent. To date, more than 60,000 Absorb BVSs have been implanted with only the interim analysis of one randomized trial (ABSORB II RCT) available. Recent registries have challenged the initial claim that BVS is immune from Scaffold Thrombosis (ST). However, suboptimal device expansion and insufficient intracoronary imaging guidance can explain higher than expected ST, especially in complex lesions. The aim of this review article is to critically evaluate the results of the available Absorb BVS studies and discuss the lessons learned to optimize lesion selection and implantation technique of such devices.

Absorb bioresorbable vascular scaffold: What have we learned after 5 years of clinical experience? / Caiazzo, Gianluca; Kilic, Ismail Dogu; Fabris, Enrico; Serdoz, Roberta; Mattesini, Alessio; Foin, Nicolas; De Rosa, Salvatore; Indolfi, Ciro; Di Mario, Carlo. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - ELETTRONICO. - 201:(2015), pp. 129-136. [10.1016/j.ijcard.2015.07.101]

Absorb bioresorbable vascular scaffold: What have we learned after 5 years of clinical experience?

Mattesini, Alessio;Di Mario, Carlo
2015

Abstract

Bioresorbable scaffolds have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by persistent metallic foreign body. Early clinical studies using the first commercially available drug-eluting bioresorbable vascular scaffold (BVS) reported very promising safety and efficacy outcomes, comparable to best-in-class second-generation drug-eluting metal stent. To date, more than 60,000 Absorb BVSs have been implanted with only the interim analysis of one randomized trial (ABSORB II RCT) available. Recent registries have challenged the initial claim that BVS is immune from Scaffold Thrombosis (ST). However, suboptimal device expansion and insufficient intracoronary imaging guidance can explain higher than expected ST, especially in complex lesions. The aim of this review article is to critically evaluate the results of the available Absorb BVS studies and discuss the lessons learned to optimize lesion selection and implantation technique of such devices.
2015
201
129
136
Caiazzo, Gianluca; Kilic, Ismail Dogu; Fabris, Enrico; Serdoz, Roberta; Mattesini, Alessio; Foin, Nicolas; De Rosa, Salvatore; Indolfi, Ciro; Di Mario, Carlo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1135855
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 53
social impact