A typical echograph transmits ultrasound signals and receives backscattered echoes through several tens of small transducers that compose the array of the probe. The system should process the acquired echoes in a very short time, typically few tens of ms, so that the medical doctor does not perceive any delay between the probe movements and the image update. This implies, especially when high-frame rate is required, the real-time processing of several GB of data per second: a huge constraint that is even emphasized in the new advanced ultrasound modalities investigated nowadays. In this paper, we present a Field Programmable Gate Array architecture which uses a combination of parallel and serial strategies capable to achieve a throughput rate of 3.5GB/s in ultrasound data processing. The proposed architecture is implemented in the research ultrasound system ULA-OP 256. The performance of this approach is demonstrated by the real-time implementation of Plane Wave Vector Doppler, a novel investigation method that shows the blood velocity fields over a 2D section of an artery. Tests in a carotid artery of a volunteer are presented.

FPGA-Based Multi Cycle Parallel Architecture for Real-Time Processing in Ultrasound Applications / Valentino Meacci, Enrico Boni, Alessandro Dallai, Alessandro Ramalli, Monica Scaringella, Francesco Guidi, Dario Russo, Stefano Ricci. - STAMPA. - 550:(2019), pp. 295-301. (Intervento presentato al convegno Applepies 2018 tenutosi a Pisa nel 26-27 settembre 2018) [10.1007/978-3-030-11973-7_34].

FPGA-Based Multi Cycle Parallel Architecture for Real-Time Processing in Ultrasound Applications

Valentino Meacci
;
Enrico Boni;Alessandro Dallai;Alessandro Ramalli;Monica Scaringella;Francesco Guidi;Dario Russo;Stefano Ricci
2019

Abstract

A typical echograph transmits ultrasound signals and receives backscattered echoes through several tens of small transducers that compose the array of the probe. The system should process the acquired echoes in a very short time, typically few tens of ms, so that the medical doctor does not perceive any delay between the probe movements and the image update. This implies, especially when high-frame rate is required, the real-time processing of several GB of data per second: a huge constraint that is even emphasized in the new advanced ultrasound modalities investigated nowadays. In this paper, we present a Field Programmable Gate Array architecture which uses a combination of parallel and serial strategies capable to achieve a throughput rate of 3.5GB/s in ultrasound data processing. The proposed architecture is implemented in the research ultrasound system ULA-OP 256. The performance of this approach is demonstrated by the real-time implementation of Plane Wave Vector Doppler, a novel investigation method that shows the blood velocity fields over a 2D section of an artery. Tests in a carotid artery of a volunteer are presented.
2019
Applications in Electronics Pervading Industry, Environment and Society, Lecture Notes in Electrical Engineering
Applepies 2018
Pisa
26-27 settembre 2018
Valentino Meacci, Enrico Boni, Alessandro Dallai, Alessandro Ramalli, Monica Scaringella, Francesco Guidi, Dario Russo, Stefano Ricci
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1137033
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact