Some recent studies have described a shift from traditional reversed-phase to more hydrophilic LC chemistry for EtG determination in hair (hEtG). The reason relies on the poor retention of C8– and C18-based columns for polar compounds, even in presence of great amount of aqueous phase. This work presents the development, validation and application of a new hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-LC-MS/MS) method based on a novel zwitterionic stationary phase for the analysis of hEtG. The linearity was assessed in the range of 5–100 pg/mg hair, with a correlation coefficient of >0.99. The method was selective and sensitive, with a limit of detection (LOD) and limit of quantitation (LOQ) of 1.4 pg/mg and 4.5 pg/mg in hair, respectively. Suitable diagnostic sensitivity was achieved without the introduction of a sample purification step, or a post column solvent addition. The method was successfully applied to real hair samples after full validation. This method, based on a separation at neutral conditions, confirmed the optimum retention and thus selectivity for weak acids in zwitterionic HILIC columns.

Novel zwitterionic HILIC stationary phase for the determination of ethyl glucuronide in human hair by LC-MS/MS / Palumbo, Diego; Fais, Paolo; Calì, Anna; Lusardi, Monica; Bertol, Elisabetta; Pascali, Jennifer P.*. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - STAMPA. - 1100-1101:(2018), pp. 33-38. [10.1016/j.jchromb.2018.09.027]

Novel zwitterionic HILIC stationary phase for the determination of ethyl glucuronide in human hair by LC-MS/MS

Palumbo, Diego;Bertol, Elisabetta;Pascali, Jennifer P.
2018

Abstract

Some recent studies have described a shift from traditional reversed-phase to more hydrophilic LC chemistry for EtG determination in hair (hEtG). The reason relies on the poor retention of C8– and C18-based columns for polar compounds, even in presence of great amount of aqueous phase. This work presents the development, validation and application of a new hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-LC-MS/MS) method based on a novel zwitterionic stationary phase for the analysis of hEtG. The linearity was assessed in the range of 5–100 pg/mg hair, with a correlation coefficient of >0.99. The method was selective and sensitive, with a limit of detection (LOD) and limit of quantitation (LOQ) of 1.4 pg/mg and 4.5 pg/mg in hair, respectively. Suitable diagnostic sensitivity was achieved without the introduction of a sample purification step, or a post column solvent addition. The method was successfully applied to real hair samples after full validation. This method, based on a separation at neutral conditions, confirmed the optimum retention and thus selectivity for weak acids in zwitterionic HILIC columns.
2018
1100-1101
33
38
Palumbo, Diego; Fais, Paolo; Calì, Anna; Lusardi, Monica; Bertol, Elisabetta; Pascali, Jennifer P.*
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1570023218308407-main.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 665.06 kB
Formato Adobe PDF
665.06 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1138610
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 18
social impact