The University of Florence has equipped one of the most representative Florentine historical Museum, “La Specola”, of a specific microclimatic monitoring system installed in some rooms. The paper presents the results of one-year record of temperature and relative humidity, regarding a room and its showcases. The elaboration and analysis of the microclimatic data have been carried out according to the Italian Standard UNI 10829 and the Performance Index of the most important thermo-hygrometric parameters has been calculated and assessed. Moreover, a dynamic thermal simulation to assess the effectiveness of some passive refurbishment strategies has been carried out in terms of annual and monthly Performance Index and dry bulb temperature variations. The results can be extended to several historical buildings, where poor envelope performances and large windows or skylights imply not acceptable indoor environmental conditions that can even cause damage to the artefacts.
Assessment of thermo-hygrometric indicators for preventive conservation inside museums: In field monitoring and passive microclimatic control strategies applied to "la Specola" museum of Florence / Sciurpi, Fabio; Carletti, Cristina; Pierangioli, Leone. - In: IOP CONFERENCE SERIES: MATERIALS SCIENCE AND ENGINEERING. - ISSN 1757-8981. - ELETTRONICO. - 364:(2018), pp. 0-0. (Intervento presentato al convegno Florence Heri-Tech - The Future of Heritage Science and Technologies) [10.1088/1757-899X/364/1/012023].
Assessment of thermo-hygrometric indicators for preventive conservation inside museums: In field monitoring and passive microclimatic control strategies applied to "la Specola" museum of Florence
Sciurpi, Fabio
;Carletti, Cristina;Pierangioli, Leone
2018
Abstract
The University of Florence has equipped one of the most representative Florentine historical Museum, “La Specola”, of a specific microclimatic monitoring system installed in some rooms. The paper presents the results of one-year record of temperature and relative humidity, regarding a room and its showcases. The elaboration and analysis of the microclimatic data have been carried out according to the Italian Standard UNI 10829 and the Performance Index of the most important thermo-hygrometric parameters has been calculated and assessed. Moreover, a dynamic thermal simulation to assess the effectiveness of some passive refurbishment strategies has been carried out in terms of annual and monthly Performance Index and dry bulb temperature variations. The results can be extended to several historical buildings, where poor envelope performances and large windows or skylights imply not acceptable indoor environmental conditions that can even cause damage to the artefacts.File | Dimensione | Formato | |
---|---|---|---|
Sciurpi_2018_IOP_Conf._Ser.__Mater._Sci._Eng._364_012023.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
797.69 kB
Formato
Adobe PDF
|
797.69 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.