Background: For the evaluation in humans of structural alterations in resistance arteries, most studies have used an indirect index, the measurement of minimal vascular resistance (mean blood pressure divided by maximal postischaemic blood flow) in suitable vascular beds. A sensitive and specific micromyographic technique was recently made available for the study of human small resistance arteries. Whether a correlation really exists between results obtained with the two techniques has not yet been investigated. Objective: To evaluate both forearm minimal vascular resistance and media:lumen ratio of omental or subcutaneous small arteries in normotensive subjects and hypertensive patients. Design and methods: Thirty-four individuals were included in the study (age range 35-74 years; 24 hypertensive, 10 normotensive). Twenty-five had elective abdominal surgery and nine hypertensive patients had a gluteal biopsy. Omental and subcutaneous small arteries were dissected and mounted on a wire micromyograph (Mulvany's technique), and media:lumen ratio and media thickness were measured. The dose-response curve to noradrenaline was constructed at cumulative concentrations from 3 x 10(-9) to 3 x 10(-5) mol/l. Venous occlusion plethysmography was used to measure blood flow in the forearm, and minimal vascular resistance was calculated from mean blood pressure and postischaemic maximal blood flow (13 min ischaemia plus exercise). Results: A statistically significant correlation was found between media:lumen ratio and minimal vascular resistance (r = 0.74, P < 0.001) as well as between media: lumen ratio and systolic (r = 0.44, P < 0.01 ) and diastolic (r = 0.38, P < 0.05) blood pressures. Similar correlations were observed between media thickness and systolic and diastolic blood pressures. Smalt arteries from hypertensive patients had a significantly increased reactivity to noradrenaline (by analysis of variance) compared with those from normotensive subjects, in terms of wall tension but not of active media stress. Conclusions: The present study demonstrated that the media:lumen ratio of small resistance vessels is significantly related to forearm minimal vascular resistance, suggesting that direct and indirect evaluations of vascular morphology will give similar results. RI Rizzoni, Damiano/E-9967-2010; Muiesan, Maria Lorenza /C-1111-2011; Salvetti, Massimo/E-9929-2010; Castellano, Maurizio/C-1096-2011

MEDIA/LUMEN RATIO IN HUMAN SMALL RESISTANCE ARTERIES IS RELATED TO FOREARM MINIMAL VASCULAR-RESISTANCE / ROSEI EA; RIZZONI D; CASTELLANO M; PORTERI E; ZULLI R; MUIESAN ML; BETTONI G; SALVETTI M; MUIESAN P; GIULINI SM. - In: JOURNAL OF HYPERTENSION. - ISSN 0263-6352. - 13:(1995), pp. 341-347.

MEDIA/LUMEN RATIO IN HUMAN SMALL RESISTANCE ARTERIES IS RELATED TO FOREARM MINIMAL VASCULAR-RESISTANCE

MUIESAN P;
1995

Abstract

Background: For the evaluation in humans of structural alterations in resistance arteries, most studies have used an indirect index, the measurement of minimal vascular resistance (mean blood pressure divided by maximal postischaemic blood flow) in suitable vascular beds. A sensitive and specific micromyographic technique was recently made available for the study of human small resistance arteries. Whether a correlation really exists between results obtained with the two techniques has not yet been investigated. Objective: To evaluate both forearm minimal vascular resistance and media:lumen ratio of omental or subcutaneous small arteries in normotensive subjects and hypertensive patients. Design and methods: Thirty-four individuals were included in the study (age range 35-74 years; 24 hypertensive, 10 normotensive). Twenty-five had elective abdominal surgery and nine hypertensive patients had a gluteal biopsy. Omental and subcutaneous small arteries were dissected and mounted on a wire micromyograph (Mulvany's technique), and media:lumen ratio and media thickness were measured. The dose-response curve to noradrenaline was constructed at cumulative concentrations from 3 x 10(-9) to 3 x 10(-5) mol/l. Venous occlusion plethysmography was used to measure blood flow in the forearm, and minimal vascular resistance was calculated from mean blood pressure and postischaemic maximal blood flow (13 min ischaemia plus exercise). Results: A statistically significant correlation was found between media:lumen ratio and minimal vascular resistance (r = 0.74, P < 0.001) as well as between media: lumen ratio and systolic (r = 0.44, P < 0.01 ) and diastolic (r = 0.38, P < 0.05) blood pressures. Similar correlations were observed between media thickness and systolic and diastolic blood pressures. Smalt arteries from hypertensive patients had a significantly increased reactivity to noradrenaline (by analysis of variance) compared with those from normotensive subjects, in terms of wall tension but not of active media stress. Conclusions: The present study demonstrated that the media:lumen ratio of small resistance vessels is significantly related to forearm minimal vascular resistance, suggesting that direct and indirect evaluations of vascular morphology will give similar results. RI Rizzoni, Damiano/E-9967-2010; Muiesan, Maria Lorenza /C-1111-2011; Salvetti, Massimo/E-9929-2010; Castellano, Maurizio/C-1096-2011
1995
13
341
347
ROSEI EA; RIZZONI D; CASTELLANO M; PORTERI E; ZULLI R; MUIESAN ML; BETTONI G; SALVETTI M; MUIESAN P; GIULINI SM
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1168570
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 78
social impact