Abstract OBJECTIVE: The aim of this study was to propose and verify a universal method of left ventricular myocardium segmentation, able to operate on heart gated PET data with different sizes, shapes and uptake distributions. The proposed method can be classified as active model method and is based on the BEAS (B-spline Explicit Active Surface) algorithm published by Barbosa et al. The method was implemented within the Pmod PCARD software package. Method verification by comparison with reference software and phantom data is also presented in the paper. METHODS: The proposed method extends the BEAS model by defining mechanical features of the model: tensile strength and bending resistance. Formulas describing model internal energy increase during its stretching and bending are proposed. The segmentation model was applied to the data of 60 patients, who had undergone cardiac gated PET scanning. QGS by Cedars-Sinai and ECTb by Emory University Medical Centre served as reference software for comparing ventricular volumes. The method was also verified using data of left ventricular phantoms of known volume. RESULTS: The results of the proposed method are well correlated with the results of QGS (slope: 0.841, intercept: 0.944 ml, R2: 0.867) and ECTb (slope: 0.830, intercept: 2.109 ml, R2: 0.845). The volumes calculated by the proposed method were very close to the true cavity volumes of two different phantoms. CONCLUSIONS: The analysis of gated PET data by the proposed method results in volume measurements comparable to established methods. Phantom experiments demonstrate that the volume values correspond to the physical ones.

Novel 3D heart left ventricle muscle segmentation method for PET-gated protocol and its verification / Kubik T.; Kaluzynski K.; Burger C.; Passeri A.; Margiacchi S.; Saletti P.; Bonini R.; Lorenzini E.; Sciagra R.. - In: ANNALS OF NUCLEAR MEDICINE. - ISSN 0914-7187. - STAMPA. - 33:(2019), pp. 629-638. [10.1007/s12149-019-01373-6]

Novel 3D heart left ventricle muscle segmentation method for PET-gated protocol and its verification

Passeri A.
;
MARGIACCHI, SELENE
;
Saletti P.
;
Sciagra R.
2019

Abstract

Abstract OBJECTIVE: The aim of this study was to propose and verify a universal method of left ventricular myocardium segmentation, able to operate on heart gated PET data with different sizes, shapes and uptake distributions. The proposed method can be classified as active model method and is based on the BEAS (B-spline Explicit Active Surface) algorithm published by Barbosa et al. The method was implemented within the Pmod PCARD software package. Method verification by comparison with reference software and phantom data is also presented in the paper. METHODS: The proposed method extends the BEAS model by defining mechanical features of the model: tensile strength and bending resistance. Formulas describing model internal energy increase during its stretching and bending are proposed. The segmentation model was applied to the data of 60 patients, who had undergone cardiac gated PET scanning. QGS by Cedars-Sinai and ECTb by Emory University Medical Centre served as reference software for comparing ventricular volumes. The method was also verified using data of left ventricular phantoms of known volume. RESULTS: The results of the proposed method are well correlated with the results of QGS (slope: 0.841, intercept: 0.944 ml, R2: 0.867) and ECTb (slope: 0.830, intercept: 2.109 ml, R2: 0.845). The volumes calculated by the proposed method were very close to the true cavity volumes of two different phantoms. CONCLUSIONS: The analysis of gated PET data by the proposed method results in volume measurements comparable to established methods. Phantom experiments demonstrate that the volume values correspond to the physical ones.
2019
33
629
638
Kubik T.; Kaluzynski K.; Burger C.; Passeri A.; Margiacchi S.; Saletti P.; Bonini R.; Lorenzini E.; Sciagra R.
File in questo prodotto:
File Dimensione Formato  
Kubik2019_Article_Novel3DHeartLeftVentricleMuscl.pdf

Accesso chiuso

Descrizione: Articolo
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.57 MB
Formato Adobe PDF
1.57 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1169348
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact