An advanced seismic retrofit strategy of industrial buildings with reinforced concrete structure is presented in this article. It consists in seismically isolating the roof and installing fluid viscous dampers at the roof girder-to-column joints, in the girder vertical plan, and at the ends of the longitudinal beams linking the column top sections, in the orthogonal direction. A retrofit solution based on this strategy is demonstratively designed for a representative case study, i.e. a single storey double hall-type prefab structure built in the late 1980s. A synthesis of the results of the analyses carried out in current conditions is offered, which highlights near-collapse conditions at the maximum considered earthquake level. The response in retrofitted conditions results to be safe and undamaged up to the same seismic action level, thanks to the high damping capacity of the dissipative joints. The structural installation details of the protective system are illustrated, along with technological details of the pipes crossing the isolated roof plan.

Incorporation of dissipative connections for seismic retrofit of reinforced concrete prefab structures / S. Sorace; G. Terenzi; A. Frangipane. - In: INGEGNERIA SISMICA. - ISSN 0393-1420. - STAMPA. - Anno XXXVI:(2019), pp. 55-65.

Incorporation of dissipative connections for seismic retrofit of reinforced concrete prefab structures

G. Terenzi;
2019

Abstract

An advanced seismic retrofit strategy of industrial buildings with reinforced concrete structure is presented in this article. It consists in seismically isolating the roof and installing fluid viscous dampers at the roof girder-to-column joints, in the girder vertical plan, and at the ends of the longitudinal beams linking the column top sections, in the orthogonal direction. A retrofit solution based on this strategy is demonstratively designed for a representative case study, i.e. a single storey double hall-type prefab structure built in the late 1980s. A synthesis of the results of the analyses carried out in current conditions is offered, which highlights near-collapse conditions at the maximum considered earthquake level. The response in retrofitted conditions results to be safe and undamaged up to the same seismic action level, thanks to the high damping capacity of the dissipative joints. The structural installation details of the protective system are illustrated, along with technological details of the pipes crossing the isolated roof plan.
2019
Anno XXXVI
55
65
S. Sorace; G. Terenzi; A. Frangipane
File in questo prodotto:
File Dimensione Formato  
Articolo prefab pubblicato.pdf

Accesso chiuso

Descrizione: articolo pubblicato
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.37 MB
Formato Adobe PDF
1.37 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1171675
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact