In this work we present the response of a new large volume 4H Silicon Carbide (SiC) detector to 14 MeV neutrons. The device has an active thickness of 100um (obtained by epitaxial growing) and an active area of 25 mm^2. Tests were conducted at the ENEA-Frascati Neutron Generator facility by using 14.1 MeV neutrons. The SiC detector performance was compared to that of Single-Crystal Diamond (SCD) detectors. The SiC response function was successfully measured and revealed a very complex structure due to the presence in the detector of both Silicon and Carbon atoms. Nevertheless, the flexibility in the SiC manufacturing and the new achievements in terms of relatively large areas (up 1x1 cm^2) and a wide range of thicknesses makes them an interesting alternative to diamond detectors in environments where limited space and high neutron fluxes are an issue, i.e. modern neutron cameras or in-vessel tokamak measurements for the new generation fusion machines such as ITER. The absence of instabilities during neutron irradiation and the capability to withstand high neutron fluences and to follow the neutron yield suggest a straightforward use of these detectors as a neutron diagnostics.

New thick silicon carbide detectors: Response to 14 MeV neutrons and comparison with single-crystal diamonds / Rebai M.; Rigamonti D.; Cancelli S.; Croci G.; Gorini G.; Perelli Cippo E.; Putignano O.; Tardocchi M.; Altana C.; Angelone M.; Borghi G.; Boscardin M.; Ciampi C.; Cirrone G.A.P.; Fazzi A.; Giove D.; Labate L.; Lanzalone G.; La Via F.; Loreti S.; Muoio A.; Ottanelli P.; Pasquali G.; Pillon M.; Puglia S.M.R.; Santangelo A.; Trifiro A.; Tudisco S.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - ELETTRONICO. - 946:(2019), pp. 0-0. [10.1016/j.nima.2019.162637]

New thick silicon carbide detectors: Response to 14 MeV neutrons and comparison with single-crystal diamonds

Ciampi C.;FAZZI, ANNA;Labate L.;Ottanelli P.;Pasquali G.;Santangelo A.;
2019

Abstract

In this work we present the response of a new large volume 4H Silicon Carbide (SiC) detector to 14 MeV neutrons. The device has an active thickness of 100um (obtained by epitaxial growing) and an active area of 25 mm^2. Tests were conducted at the ENEA-Frascati Neutron Generator facility by using 14.1 MeV neutrons. The SiC detector performance was compared to that of Single-Crystal Diamond (SCD) detectors. The SiC response function was successfully measured and revealed a very complex structure due to the presence in the detector of both Silicon and Carbon atoms. Nevertheless, the flexibility in the SiC manufacturing and the new achievements in terms of relatively large areas (up 1x1 cm^2) and a wide range of thicknesses makes them an interesting alternative to diamond detectors in environments where limited space and high neutron fluxes are an issue, i.e. modern neutron cameras or in-vessel tokamak measurements for the new generation fusion machines such as ITER. The absence of instabilities during neutron irradiation and the capability to withstand high neutron fluences and to follow the neutron yield suggest a straightforward use of these detectors as a neutron diagnostics.
2019
946
0
0
Rebai M.; Rigamonti D.; Cancelli S.; Croci G.; Gorini G.; Perelli Cippo E.; Putignano O.; Tardocchi M.; Altana C.; Angelone M.; Borghi G.; Boscardin M...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1175398
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 23
social impact