A study concerning the performance assessment and enhanced retrofit of public buildings originallydesignedwithoutanyanti-seismicprovisionsispresentedherein. Arepresentativestructure belonging to this class was demonstratively examined, i.e., a school built in Italy in the early 1970s, before a coordinate national Seismic Standard was issued. The building is characterized by a mixed reinforced concrete (ground storey)–steel (first and second storey) frame skeleton. An extensive on-site experimental investigation was developed in the first step of the study, which helped identify the mechanical characteristics of the constituting materials, and re-draw the main structural details. Based on these data, and relevant updates of the finite element model of the structure, the seismic assessment analyses carried out in current conditions highlighted several performance deficiencies, in both the reinforced concrete and steel members. An advanced seismic retrofit hypothesis of the building was then designed, consisting of the installation of a set of dissipative braces incorporating fluid viscous dampers as protective devices. This solution makes it possible to attain an elastic structural response up to the maximum considered normative earthquake level, while at the same time causing more limited architectural intrusion and lower costs as compared to conventional rehabilitation strategies.
Advanced Seismic Retrofit of a Mixed R/C-Steel Structure / Gloria Terenzi; Caterina Bazzani; Iacopo Costoli; Stefano Sorace; Paolo Spinelli. - In: BUILDINGS. - ISSN 2075-5309. - ELETTRONICO. - 9(12):(2019), pp. 1-16. [10.3390/buildings9120241]
Advanced Seismic Retrofit of a Mixed R/C-Steel Structure
Gloria Terenzi;Caterina Bazzani;Iacopo Costoli;Paolo Spinelli
2019
Abstract
A study concerning the performance assessment and enhanced retrofit of public buildings originallydesignedwithoutanyanti-seismicprovisionsispresentedherein. Arepresentativestructure belonging to this class was demonstratively examined, i.e., a school built in Italy in the early 1970s, before a coordinate national Seismic Standard was issued. The building is characterized by a mixed reinforced concrete (ground storey)–steel (first and second storey) frame skeleton. An extensive on-site experimental investigation was developed in the first step of the study, which helped identify the mechanical characteristics of the constituting materials, and re-draw the main structural details. Based on these data, and relevant updates of the finite element model of the structure, the seismic assessment analyses carried out in current conditions highlighted several performance deficiencies, in both the reinforced concrete and steel members. An advanced seismic retrofit hypothesis of the building was then designed, consisting of the installation of a set of dissipative braces incorporating fluid viscous dampers as protective devices. This solution makes it possible to attain an elastic structural response up to the maximum considered normative earthquake level, while at the same time causing more limited architectural intrusion and lower costs as compared to conventional rehabilitation strategies.File | Dimensione | Formato | |
---|---|---|---|
buildings-09-00241 (1) pubblicato.pdf
Accesso chiuso
Descrizione: pubblicazione on-line
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
8.8 MB
Formato
Adobe PDF
|
8.8 MB | Adobe PDF | Richiedi una copia |
2019-12-19_buildings_Issue Cover-draft (1).jpg
Accesso chiuso
Descrizione: copertina del fascicolo
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
1.43 MB
Formato
JPEG
|
1.43 MB | JPEG | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.